By injecting simulated High- power CO_2 Laser operating gas into the microreactor and measuring conversion rates of nitric oxide at different tempera- tures and space rates,it is verified that such oxide can be used as a catalyst to achieve the circulating conversion of CO_2 Laser operating gas in the cavity. As a result, prolonging continuous operation time be- comes possible.