助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   光源标定 的翻译结果: 查询用时:1.508秒
图标索引 在分类学科中查询
所有学科
物理学
更多类别查询

图标索引 历史查询
 

光源标定    
相关语句
查询“光源标定”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  source calibration
Dual source calibration and decaying source techniques are used in the evaluation of the accuracy of the correction technique.
      
Other unique features of the LECP include logarithmic amplifiers, particle identifiers, fast (~15 ns FWHM) pulse circuitry for some subsystems, inflight electronic and source calibration and several possible data modes.
      
Modification of the comparison method for the moving-source calibration of hydrophones in a shallow sea
      
A QA programme cannot rest on a source calibration alone, but in addition it should address all the different steps included in the treatment process.
      
An electronic system was used to control the light source calibration when an experiment was initiated.
      
更多          


Using a multichannel quartz optical-fiber system calibrated with a standard tungsten strip lamp,the radial profiles of the visible bremsstrahlung radiation power in the HL-1 tokamak were measured.The measured radial profiles of the effective ionic charge number Zeff are peaked at the plasma center.The results obtained show that,in a single discharge,an increase in electron density decreases Zeff significantly.In a number of discharges,by increasing the electron density with gas puffing,the central chord average...

Using a multichannel quartz optical-fiber system calibrated with a standard tungsten strip lamp,the radial profiles of the visible bremsstrahlung radiation power in the HL-1 tokamak were measured.The measured radial profiles of the effective ionic charge number Zeff are peaked at the plasma center.The results obtained show that,in a single discharge,an increase in electron density decreases Zeff significantly.In a number of discharges,by increasing the electron density with gas puffing,the central chord average Zeff can be reduced notably,while an increase in the plasma current Ip leads to an in crease in Zeff MARFE phenomena were observed in several discharges.

采用经钨带灯标准光源标定的多道石英光纤光学系统,测量了HL-1装置等离子体可见光波段轫致辐射功率的径向分布。测得的有效离子电荷数Z_(eff)的径向分布在中心处有最大值。放电过程中电子密度的增大使Z_(eff)降低。不同放电条件下的实验结果表明,用脉冲送气提高电子密度,可使中心弦平均Z_(eff)显著降低,而等离子体电流I_p的增大使Z_(eff)上升。在若干次放电中观测到了MARFE现象。

By using the strong L-lines emitted from Cu plasma as pulse X-ray source produced by irradiating Cu target with a 1. 06 μm pulse laser of the LF-11 laser facility,the reponses of X-ray film Kodak AA-5, Kodak SWR and UFSH-O were calibrated.Calibrated responses with the pulse X-ray source were compared with that with continuum X-ray source (fluoresent source exciteed by protons ). These results showed the reciprocity failure. The response to continuum X-ray source is not suitable for the diagnostics in laser-induced...

By using the strong L-lines emitted from Cu plasma as pulse X-ray source produced by irradiating Cu target with a 1. 06 μm pulse laser of the LF-11 laser facility,the reponses of X-ray film Kodak AA-5, Kodak SWR and UFSH-O were calibrated.Calibrated responses with the pulse X-ray source were compared with that with continuum X-ray source (fluoresent source exciteed by protons ). These results showed the reciprocity failure. The response to continuum X-ray source is not suitable for the diagnostics in laser-induced plasma.

用LF-11激光装置的1.06μm脉冲激光加热Cu靶产生的L-壳层线辐射作脉冲X射线源,在曝光量为(0.01~10)-7J·cm-2范围内,标定了KODAKAA-5,KODAKSWR和UFSH-O软X射线胶片的响应曲线,并与用连续光源标定的进行了对比.结果表明,这三种x射线胶片,在强脉冲光源曝光条件下,都存在着胶片响应互易律失效问题,过去用连续光源标定的响应曲线,在激光等离子体诊断实验中,已经不能采用.

In this paper, the research work of spectral radiometric standards established by using synchrotron radiation has been reviewed. The radiometric transfer standard sources were briefly described, Finally the method of calibration was introduced.

介绍国内外用同步辐射建立光谱辐射标准的概况,同时介绍在同步辐射标准应用中所需的几种常用的传递标准光源,以及用同步辐射完成传递标准光源标定涉及的辐射测试技术。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关光源标定的内容
在知识搜索中查有关光源标定的内容
在数字搜索中查有关光源标定的内容
在概念知识元中查有关光源标定的内容
在学术趋势中查有关光源标定的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社