  main insulation structure
     Firstly, for the 10kV voltage class, the main insulation distance has been reduced from 9.5mm to 7.5mm. By analyzing and calculating the two kinds structures the rationality of new main insulation structure can be obtained.
     对于10kV级主绝缘结构,首先提出新的主绝缘结构尺寸,主空道尺寸由9.5mm减小为7.5mm,对两种结构分别进行计算与分析,通过对计算结果的分析,论证了新型主绝缘结构尺寸的合理性。
短句来源
     The new design schemes of main insulation structure are presented to the power transformers of 10kV, 35kV, and 110kV voltage class respectively.
     分别对10kV级,35kV级,110kV级三种电压等级的主绝缘结构提出了新的设计方案。
短句来源
     Study on the New Type of Main Insulation Structure of Electric Power Transformer
     电力变压器新型主绝缘结构的研究
短句来源
     Secondly, for the 35kV voltage class, the electric field is concentrative overly if the main insulation distance has been reduced from 27mm to 18mm, so a special method must be adopted to guarantee the reliability. Comparing the manufacturing cost of the two examples, the advantage and practicability of the new main insulation structure is feasible.
     对于35kV级主绝缘结构,新的主绝缘结构尺寸是主空道尺寸由27mm减小为18mm,通过对两种结构分别进行计算与分析,发现新绝缘结构中电场分布过度集中,需要采取相应措施,保证主绝缘结构的可靠性,最后得出结论:新型主绝缘结构是可行的,并通过两个实例进行了制造成本的对比,进一步说明了新型主绝缘结构的先进性和实用性。
短句来源
     Thirdly, for the 110kV voltage class, the new main insulation structure is feasible according to the calculation and test report, even if the main insulation distance has been reduced from 40mm to 38mm.
     对于110kV级主绝缘结构,主空道尺寸由40mm减小为38mm,通过计算与分析及SZ10-16000/110产品试验合格报告的验证,最后得出结论:新型主绝缘结构是可行的。
短句来源
更多       
  the main insulating structure
     In this paper, the theory of small oil gap was used in design of the main insulating structure of the 10、35kV power transformer. The new main insulating structure was systematically and experimentally studied with the numerical calculation of winding end electrical field and the breakdown experiment on transformer model.
     本文将小油隙理论用于10、35kV变压器主绝缘结构设计中,应用绕组端部电场的数值计算、主绝缘结构模型的工频和冲击击穿试验,对所提出的新型10、35kV变压器主绝缘结构进行了试验研究.
短句来源
  main insulating structures
     Testing Study of the Main Insulating Structures in 10、35kV Power Transformer
     10、35kV级变压器主绝缘结构试验研究
短句来源
     And then, some improved new main insulating structures of 10、35kV power transformet are offered.
     从而提出了合理的10、35kV变压器主绝缘结构尺寸.
短句来源
  “主绝缘结构”译为未确定词的双语例句
     Test Research on Main Insulation of 10kV & 35kV Transformers
     10kV、35kV变压器主绝缘结构的试验研究
短句来源
     Study on Main Insulation System of Converter Transformer for ±800kV HVDC Power Transmission Project
     ±800kV直流输电工程用换流变压器主绝缘结构的研究
短句来源
     Based on above analysis and calculation, the conclusions are derived that the new insulation structure of 10kV, 35kV, and 110kV voltage class are advanced and meets the requirements of reliability.
     通过本文的分析,最后得出结论:本文所提出的10kV级,35kV级,110kV级新型主绝缘结构尺寸经过电场计算都是满足要求的,是先进的主绝缘结构尺寸。
短句来源
     The electric stress along the electric force line were transferred into mean value of every oil gap, compared it with permit curve so as to realize the reliability evaluation.
     即以电场数值计算结果为出发点,将场域中沿电力线各单元的电场强度转换为油隙的平均电场强度,并与许用值曲线进行对比,以实现变压器主绝缘结构的可靠性评价。
     The main insulation structures of present 10kV and 35kV transformers are analyzed. The new structures of main insulation in 10kV and 35kV transformers are given. The related test and research are presented.
     对现有的10kV、35kV变压器主绝缘结构进行了分析,提出了10kV、35kV变压器的主绝缘新结构,介绍了所开展的有关试验研究工作。
短句来源
更多       
查询“主绝缘结构”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


In this paper, the theory of small oil gap was used in design of the main insulating structure of the 10、35kV power transformer. The new main insulating structure was systematically and experimentally studied with the numerical calculation of winding end electrical field and the breakdown experiment on transformer model. And then, some improved new main insulating structures of 10、35kV power transformet are offered.

本文将小油隙理论用于10、35kV变压器主绝缘结构设计中,应用绕组端部电场的数值计算、主绝缘结构模型的工频和冲击击穿试验,对所提出的新型10、35kV变压器主绝缘结构进行了试验研究.从而提出了合理的10、35kV变压器主绝缘结构尺寸.

The paper optimizes the construction design of the main insulation of stator coil for H. V. large generators using numerical calculating method. It. can promote the operating life and capability of generators.

用数值计算法对大电机定子线圈主绝缘结构进行了优化设计,提高绝缘运行寿命,增大电机出力。

This paper expounds the main insulation structure and technique between high and low voltage windings of high-voltage rectifier transformer for dust-removing before and after the improvement. The advantage of the improved structure is analysed from the view of breakdown strength.

阐述了改进前后除尘用高压硅整流变压器高低压绕组间的主绝缘结构和工艺,从击穿电场强度角度分析了改进后的主绝缘结构的优点。

 