  ultralow frequency test
     ultralow frequency test can effectively identify the water-tree fault in the cable;
     超低频试验能有效发现电缆的水树故障;
短句来源
  “超低频试验”译为未确定词的双语例句
     APPLICATION OF 0.1Hz AC TECT IN XLPE CABLE
     0.1Hz超低频试验在交联电缆中的应用
短句来源
     This paper introduces the application of 0.1Hz AC test to test the XLPE cable.
     介绍了 0 1Hz超低频试验在武钢交联电缆中的应用。
短句来源
     The paper describes the advantages and the new development of 0.1Hz very low frequency voltage test on stator windings of HV electrical machine,at the same time,a very low frequency 0.1Hz voltage test equipment developed by authors is presented.
     本文阐述了高压电机定子绕组 0 .1Hz超低频试验的优点及其超低频试验技术最新发展情况 ; 并介绍了研制的 0 .1Hz超低频电压试验装置
短句来源
  相似匹配句对
     Ultra-low frequency voltage endurance test for cross-linked cable
     交联电缆的低频耐压试验
短句来源
     Voltage Level Test of 0.1Hz Supper Lowe Frequency
     0.1Hz低频(SLF)耐压试验
短句来源
     An auto-measuring system for ultra-low-frequency metrology
     低频计量自动测试系统
短句来源
     The Measurement of Ultra-low Frenquency Voltage
     低频电压的测量
短句来源
     TESTING
     试验
短句来源
查询“超低频试验”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


The paper describes the advantages and the new development of 0.1Hz very low frequency voltage test on stator windings of HV electrical machine,at the same time,a very low frequency 0.1Hz voltage test equipment developed by authors is presented.

本文阐述了高压电机定子绕组 0 .1Hz超低频试验的优点及其超低频试验技术最新发展情况 ;并介绍了研制的 0 .1Hz超低频电压试验装置

The comparison made with the tests of high voltage cross linked polyethylene cable by DC voltage endurance, 0.1 Hz ultralow frequency voltage endurance, IF syntony and FM serial syntony voltage endurance indicates that DC voltage endurance test is detrimental to high voltage cross linked polyethylene insulated cable; ultralow frequency test can effectively identify the water-tree fault in the cable; serial syntony has the best equivalence; FM syntony features better equivalence and portable equipment, and there...

The comparison made with the tests of high voltage cross linked polyethylene cable by DC voltage endurance, 0.1 Hz ultralow frequency voltage endurance, IF syntony and FM serial syntony voltage endurance indicates that DC voltage endurance test is detrimental to high voltage cross linked polyethylene insulated cable; ultralow frequency test can effectively identify the water-tree fault in the cable; serial syntony has the best equivalence; FM syntony features better equivalence and portable equipment, and there is almost no limit for test sample length. A test method is recommended for the voltage endurance test of high voltage cross linked polyethylene insulated cable.

通过对高压交联聚乙烯绝缘电缆进行直流耐压、0.1Hz超低频耐压、工频谐振以及调频串联谐振耐压等试验方法的分析比较,指出直流耐压对交联聚乙烯电缆的危害;超低频试验能有效发现电缆的水树故障;串联谐振的等效性最好;调频揩振试验方法等效性较好,设备轻便,试品长度的范围几乎不受限制。针对高压交联聚乙烯绝缘电缆耐压试验方法提出了建议。

The DC test will accelerate the aging cable and shorten the operation life of XLPE. This paper introduces the application of 0.1Hz AC test to test the XLPE cable.

分析了直流试验易加速交联电缆的绝缘劣化 ,缩短其使用寿命的原因。介绍了 0 1Hz超低频试验在武钢交联电缆中的应用。

 