The accelerator can perform CABAC calculation efficiently. Performance evaluation shows the accelerator can achieve 147 Mbps(1.5 cycle/bit) encoding speed and 220 Mbps(1 cycle/bit) decoding speed under 220 MHz operation frequency,which is a speedup above 50 X,compared with software implementation.
The simulation shows the device achieves the efficiency 28% when the beam is 800 kV and 10 kA, and outputs RF power of 2.25 GW. The experiment was also carried out on Sinus-700 accelerator. The measured microwave power is 2.44 GW at the frequency 9.4G Hz.
根据此理论,根据Sinus-700加速器的参数(800kV,10kA)设计了一个X波段的高功率微波器件,2.5维Particle in Cell(PIC)程序模拟的效率为28%,微波频率为9.42GHz,微波输出功率为2.25GW,实验上得到的微波输出为微波频率9.40GHz,微波输出功率2.44GW.
The conceptual study on the accelerator driven system (ADS) that lasted for about five years ended in 1999 in China.
China's accelerator-driven sub-critical system (ADS) sub-critical experimental assembly-Venus-1 and the preliminary experiment is presented.
Radiocarbon dating of the pollen concentrate from late Pleistocene syngenetic ice wedges was carried out using accelerator mass spectrometry (AMS) in Seyakha and Bizon sections.
Sterilization of Mail by Means of an Electron Beam Accelerator
The structure of the front of an arc in a magnetohydrodynamic accelerator
This paper gives a detail illustration of a modulator which has an output of IOMW pulse peak power, 75KV peak voltage and 3μs pulse width with the repetition rate of 300pps, ±0.25% amplitude drift between pulses and ±0.5% top deviation in a pulse. The measures employed in getting the above-mentioned performances, the designing methods and the experimental results are also presented.