In Dec. 2001, 12 rainfall stations in the system have been technically modified, including converting the ultrashort wave communications to the satellite communications( Inmarsat-C), removing the original 3 mountain relay stations, keeping the 4 remote measurement stations near center station in communicating with VHF ultrashort wave.
Automatic measurement and transmission systems have been established on 25 importantreaches of flood prevention and 150 large reservoirs. Remote measurement stations amounts to about 2000 . The hy-drological inforznation departments of the 22 provinces and the 7 basin organizations have transmitted hydrologicalinformation each other through computer wide area network.
The interferential factors which influence quality of data and excluding methods in remote measurement of radon in Xiwudang spring are studied by prectical observation and a series of tests.
Consideration was given to the combinatorial hierarchical design (composition) of the structure of an application telemetry system consisting of the on-board, radio, and ground communication equipment including the operator working place.
The measurements were carried out in the real-time mode of data transmission to the Earth, when the orbital station flew over the telemetry data receiving point.
The RISS could be utilized as a water management program for irrigation reservoirs by interfacing with telemetering and telecontrol (TM/TC) technology.
A three-channel telemetering system is described for use in obtaining electroencephalograms from large farm animals and it may be used also for smaller laboratory animals.
Potentialities for remote measurement of parameters of working surfaces of optical elements and remote detection of the appearance of defects of such surfaces are studied experimentally.
We present a method for remote measurement of gas mixtures in the mid-IR region based on a newly developed fast-switching, frequency-agile optical parametric oscillator lidar transmitter.
This multi-spectrometer method allows for the accurate remote measurement of plume velocity and can therefore greatly improve the precision of volcanic or industrial gas flux measurements.
The system consists of ground and well telemeter units, and an acoustic waveguide based on a well scratcher wire is used as a communication link between them.
A small interface circuit between the Oxylog and the transmitter of a frequency modulated bio-telemeter system was designed and installed inside the Oxylog.
Open circuit VO2 measurements were done in the field by Douglas bag gas collection and in the laboratory by automated gas collection and analysis.fc was recorded with a telemeter (Polar Electro Sport Tester, PE3000).