Methods Thirty-two patients who were suspected sclerosis or obliterated disease of lower extremity arteries were performed 16-section MDCT scan with ranges of 1,100~1,200mm, thickness 5mm, pitch 1.375, increment 1.2mm. The volume of contrast agent was 120~150ml, flow rate3.5~4ml/s. Scan was started with Smart prep auto-trigger, and the duration time was 20~35s.
Disease detecting rate of each group was compared and the influence of the three factors was analyzed with statistics software of SPSS 13.0.Results: 1.Group 1(slice width 1.0mm,pitch 1.0) had the maximal accuracy of nodus detection,and there was no significant difference among groups 2-6(P>0.05);
Methods 38 cases clinically suspected of arteriosclerotic occlusive disease of lower extremities underwent CT angiography using a 16-slice scanner with range from abdominal aortic -renal arterial level to ankle joint, slice increment 2.5mm, pitch 1.375:1, reconstruction increment 1.25mm.
Methods 82 patients underwent spiral CT pulmonary angiography using Simens Somatom Plus 4 CT scanner with 3 mm slice thickness pitch 1.5, 1.2 mm reconstruction interval and 3-4 ml/s contrast medium injection rate.
Results: Images obtained with spiral scan of 3mm collimation,pitch 1,1.5,2mm reconstruction interval,or axia overlapping scan of 3mm collimation,2mm interval,or appropriate threshold showed smoothness and exquisiteness on the surface and loss artifacts.
For BA-MSCTA, 10ml of 45% contrast was injected into BA (1~2ml/s), and scan was started 5s after injection, ranging from low cervix to the bottom of lung ( pitch 5mm, no overlap reconstruction ).
CCT took 10mm slice thickness. TCT took small FOV(14cm-20cm,including one lung and mediastinum), 2-5mm slice thickness, 1-2 pitch and 40%-67% overlapping. Surface shaded display was applied in 36 of them.
The best post-processing parameters for direct scanning images and MPR images are slice thickness 0.6mm, pitch 1.5, reconstruction increment 50%, high-resolution algorithm.
Based on the principle of formation of conjugate tooth contour, the equations of the cam's pitch curve are derived.
例句来源
The continuity and symmetry of the cam's pitch curve are also analyzed.
例句来源
The satellite passes chosen for the detailed analysis and modeling lay approximately along the cusp/cleft band from afternoon till prenoon MLT sectors, thus emphasizing the pitch-angle dispersion role with respect to the dispersion due to convection.
例句来源
Some conclusions about the regime of pitch-angular diffusion into the loss cone are made.
例句来源
It is assumed that in such a cascade each i-th system (group) of profiles has its own pitch ti (i=1, 2,?, s) and constant phase shift αi of the oscillations between neighboring profiles.
The purpose of this study was to compare the spiral CT images with conventional CT images and to optimize spiral CT techniques for scanning of the lungs. At the same kV,mAs,a wire phantom,a low contrast phantom and dried lung specimens were scanned with spiral CT and conventional CT respectively. Scans obtained by using different collimation,reconstruction algorithm and pitch were compared for edge sharpness,contrast resolution,visibility of bronchi and vessels.The results showed that narrow collimat...
This article introduced a technique for obtaining cerebral angiography by means of spiral CT. Our experience show that this technique by it's easy handling, minimal invasiveness and excellent visualization of the carotid and basilar arteries at the same time may prove useful as a screening tool or replacement for conventional angiography in some patients. The following technical points were disscussed: ①Pitch: For the single spiral CT, the value of pitch must be less than 1.0. The recommended ##...
To design equitable technical factorsof spiral CT study the mechansim and influential elements of artifact and the displayed grades of threedimensional pulmonary vessels, we inflated thelungs which were drawn from fresh cadavers (n=2)and living dogs (n=2) with air after Pouring contrast into pulmonary arteies. When pitch was 1, weexamined the influence of different collimations, foons of view (FOV) and reconstruction intervals onangiography with threshold shaded surface display(SSD). Results: 1. Thin...