   efficiency of fire suppression 的翻译结果: 查询用时:0.177秒
图标索引 在分类学科中查询
所有学科
自动化技术
更多类别查询

图标索引 历史查询
 

efficiency of fire suppression
相关语句
  “efficiency of fire suppression”译为未确定词的双语例句
     The system not only enlarges the application scope of automatic sprinkler system (class B fire or class AB fire), but also greatly improve its efficiency of fire suppression.
     此系统不仅能扩大自动喷水灭火系统的应用范围 (如 B类火灾和 AB类火灾 ) ,而且可以提高系统灭火的有效性
短句来源
  相似匹配句对
     On efficiency of R&D
     关于科研开发效率的思考
短句来源
     On Efficiency
     效率的经济学解读
短句来源
     On Efficiency
     论效率
短句来源
     efficiency of screw;
     螺旋副的效率问题;
短句来源
     Fire and Craig C.
     Fire和CraigC.
短句来源
查询“efficiency of fire suppression”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  efficiency of fire suppression
This is consistent with a pattern of increased fire ignitions along the relatively low elevation urban-wildland interface, and an increase in the efficiency of fire suppression in high elevation forests.
      
Roads provide access that has increased the scale and efficiency of fire suppression, and roads create linear firebreaks that affect fire spread.
      
Roads provide access that increases the scale and efficiency of fire suppression, and roads create linear firebreaks that affect fire spread.
      


In this article, simulation experiments were conducted to study the effectiveness of water mist suppression of the fire located various positions as to different kind of materials in a confined space. The results showed: when the fire was in the water mist working range, the extinguishing time was shorter and effectiveness was higher, but when the fire was out of the water mist working range, the effectiveness would decrease rapidly. And there existed critical water flow rate for a given power fire. It's not...

In this article, simulation experiments were conducted to study the effectiveness of water mist suppression of the fire located various positions as to different kind of materials in a confined space. The results showed: when the fire was in the water mist working range, the extinguishing time was shorter and effectiveness was higher, but when the fire was out of the water mist working range, the effectiveness would decrease rapidly. And there existed critical water flow rate for a given power fire. It's not necessary to use more than a certain quantity of water flow rate, as it does not increase the efficiency of fire suppression system. So when designing water mist suppression, we should be very care of these factors.

采用模拟实验的方法 ,通过改变实验条件 ,研究室内不同种类固体可燃物 ,处于不同的位置时 ,细水雾的灭火有效性。研究发现 :当火源位于细水雾的作用范围内时 ,灭火时间较短 ,灭火性能较高 ;当火源位于细水雾的防护区域之外时 ,灭火有效性显著降低。增加细水雾的流量可以减少灭火时间。但是对一定功率的火源 ,存在临界流量 ,超过了临界流量 ,再增加细水雾的流量 ,并不能有效减少灭火时间。因此设计细水雾灭火系统时 ,应当优化上述影响因素 ,达到最佳的灭火性能

The paper introduces the performance of the water additive automatic sprinkler system. The system not only enlarges the application scope of automatic sprinkler system (class B fire or class AB fire), but also greatly improve its efficiency of fire suppression.

文章介绍了水添加剂自动喷水灭火系统的性能研究。此系统不仅能扩大自动喷水灭火系统的应用范围 (如 B类火灾和 AB类火灾 ) ,而且可以提高系统灭火的有效性

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关efficiency of fire suppression的内容
在知识搜索中查有关efficiency of fire suppression的内容
在数字搜索中查有关efficiency of fire suppression的内容
在概念知识元中查有关efficiency of fire suppression的内容
在学术趋势中查有关efficiency of fire suppression的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社