  hvdc联络线
     An H_(∞) based damping controller is presented for a HVDC link to enhance system damping under different operating conditions.
     为此,提出了一种可以在不同运行条件下增加系统阻尼的HVDC联络线H∞阻尼控制器设计方案。
短句来源
  “hvdc link”译为未确定词的双语例句
     Fauft Analysis for ±500 kV GE-NAN HVDC Link in 1991
     1991年±500kV葛南直流输电线故障统计分析
短句来源
     Fault Analysis for Ge-Nan HVDC Link in 1992
     1992年葛南直流输电线故障统计分析
短句来源
     A HVDC link with an auxiliary power/frequency controller has many advantages in both technical and economic aspects.
     在华中-华东多回高压直流(HVDC)输电系统上加装辅助功率/频率控制器具有显著的经济效益。
短句来源
     U sing the fast control capability of the HVDC link,a fuzzy rule is adopted to smooth the power transition. Also self- adaptive control techniques are incorporated into the strategy to ensure stability of the control action.
     借助于 HVDC线路的快速控制能力 ,采用模糊规则平滑地调整 HVDC输送的功率 ,并使用自适应控制技术以提高控制器的稳定性。
短句来源
     A Graphical user interface (GUI) software was developed to analyze subsynchronous oscillation (SSO) characteristics in the power system with the HVDC link, in order to improve the research efficiency and popularize the research results.
     为提高研究效率并普及研究结果,开发了一个用于分析HVDC输电系统次同步振荡(SSO)特性的图形用户界面(GUI)软件。
短句来源
更多       
  相似匹配句对
     Link
     链接
短句来源
     Link.
     Link。
短句来源
     Fault Analysis for Ge-Nan HVDC Link in 1992
     1992年葛南直流输电线故障统计分析
短句来源
     CALCULATION OF TELECOMMUNICATION INTERFERENCE CAUSED BY THREE GORGES GUANGDONG HVDC LINK
     三峡——广东直流线路电信干扰计算
短句来源
     HVDC Transmission Technology
     高压直流输电技术
短句来源
查询“hvdc link”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  hvdc link
The results demonstrate that the best damper may not be installed at the location with the most onerous vibrations but provides satisfactory damping performance on shafts and blades following severe power disturbances in a HVDC link.
      
Due to more various power disturbances occurring in a power system involving a HVDC link, the turbine generator shafts and/or blades are more prone to damage than in general HVAC systems.
      
A New Damper Scheme to Restrict Torsional Torques on the Turbine Generator Shafts and Blades near a HVDC Link
      
The conventional method of calculating high-voltage direct current (HVDC) converter commutation angles can result in very inaccurate results if the ripple of the DC is fairly high, or the HVDC link consists of capacitor commutated converters (CCC).
      
The controller of the HVDC tap is independent from the master control of the HVDC link.
      
更多          


It is the first time to present a method of sensitivity analysis of parameters for reliability evaluation of HVDC systems in this paper. Recently, the sensitivity analysis is evidently a necessary aspect for reliability evaluation in an engineering system, because of some indeterminate factors, especially the original parameters of reliability.The basic Markov Processes Theory and techniques of differential of complex functions are employed to develop the new method in this paper. The main relevent formulas...

It is the first time to present a method of sensitivity analysis of parameters for reliability evaluation of HVDC systems in this paper. Recently, the sensitivity analysis is evidently a necessary aspect for reliability evaluation in an engineering system, because of some indeterminate factors, especially the original parameters of reliability.The basic Markov Processes Theory and techniques of differential of complex functions are employed to develop the new method in this paper. The main relevent formulas are deduced and the computer approach is in general described. The reliability indices calculated for HVDC systems are state probabilities Pi, frequencies Fi and mean durations Di for each capacity which HVDC systems ecounter in operation. The sensitivities, such as Pi/(?)ai, (?)Fi/(?)ai and (?)Di/(?)ai, can be obtained by using this method proposed at the same time when the maih reliability indices of the system are evaluated, where ai is one of the parameters, such as failure rates, repair rates etc., of components of HVDC systems. A comprehensive example of Gezhouba to Shanghai HVDC Link is given to illustrate the application of the method proposed in this paper, and it shows that this method is simple and efficient for practical applications of reliability evaluation in HVDC systems.

本文根据Markov过程的基本理论,运用复合函数求导的方法,首次对高压直流系统可靠性评估中的参数灵敏度进行了分析。推导了主要数学公式,并提出了相应的计算机方法。本文所提出的方法已在葛洲坝—上海的高压直流系统中得到了应用,并取得了有意义的结果。

Refering to the results of the end to end system tests for GESHA HVDC Project, this paper describes the important operating characteristics of a HVDC link within AC/DC hybrid power system. It is useful for considering the functions of a HVDC link in studying interconnection of regional power grids in our country.

本文结合葛上直流输电工程双极系统调试结果,介绍混合电力输电网中,直流系统的主要运行特点。这有益于在研究区域电网互联时,充分考虑并发挥直流输电系统应有的作用。

The state estimation of multiterminal AC-DC power system is discussed in the paper-A new and simple model of HVDC Link with a select of 4 state variables and 10 possible measurements (including 2 pseudomeasurements) at each terminal of the link is assumed. The DC state variables so chosen not only assess the performance state of the HVDC link,simplify the formation of the Jacobian matrix, but also characterize the interconnection of the AC and DC systems. With this modelling, the unified method...

The state estimation of multiterminal AC-DC power system is discussed in the paper-A new and simple model of HVDC Link with a select of 4 state variables and 10 possible measurements (including 2 pseudomeasurements) at each terminal of the link is assumed. The DC state variables so chosen not only assess the performance state of the HVDC link,simplify the formation of the Jacobian matrix, but also characterize the interconnection of the AC and DC systems. With this modelling, the unified method and vari- ous decoupled methods (AC-DC,P-QDC,P-Q-DC)of state estimation are investigated under random noise statistical simulations both in'strongly' and 'weakly' connected AC-DC systems.The simulation tests show that the proposed DC modelling is feasible, and the results of estimation of these methods are all acceptable in strongly connected AC-DC systems. The P-Q-DC method, due to its low computing time and storage and its capability to be treated by parallel computation, is most noteworthy.However, in the weakly connected system, the convergence of P-Q-DC method becomes slow. Measures to overcome this phenomenon are investigated in the paper. One way is to adopt deceleration factor in the iteration process. Its effect proves to be quite satisfactory, not being restricted by the mode of HVDC operation. Thus, the P-Q-DC method conld be used effectively in the state estimation of multiterminal AC-DC power system, both for strongly and for weakly connected systems.The problem of detectability and identifiability of bad data in HVDC link measurements has not been discussed fully so far. Result of simulation tests in the paper shows that the theory of detection and identification of bad data in AC system can be extended to multiterminal AC-DC system. This problem has been fully considered and the proposed measurement set in HVDC link in the paper proves to be meeting the requirements of bad data detectability and identifiability.

本文讨论了多端交直流联合系统状态估计的直流系统模型,并对联立法和各种解耦算法在随机误差环境下进行了模拟试验和评价。对P-Q-DC法应用于弱交流系统时使其收敛性变差的问题提出了改进措施,取得了令人满意的效果。本文还讨论了P-Q-DC法中直流系统量测的不良数据的检测和辨识问题。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关hvdc link的内容
在知识搜索中查有关hvdc link的内容
在数字搜索中查有关hvdc link的内容
在概念知识元中查有关hvdc link的内容
在学术趋势中查有关hvdc link的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社