   static voltage collapse critical point 的翻译结果: 查询用时:0.008秒
图标索引 在分类学科中查询
所有学科
更多类别查询

图标索引 历史查询
 

static voltage collapse critical point
相关语句
  静态电压稳定临界点
     Determination of Static Voltage Collapse Critical Point Based on Load Flow Method with Optimal Multiplier
     基于最优乘子潮流确定静态电压稳定临界点
短句来源
     A new method for determination of static voltage collapse critical point based on Newton-Raphson load flow method with optimal multiplier is proposed in this paper.
     给出了一种基于最优乘子潮流求静态电压稳定临界点的新方法。
短句来源
  相似匹配句对
     THE INVESTIGATION TO VOLTAGE STATIC STABILITY
     电压静态稳定性探讨
短句来源
     Judgement of static voltage stability in power system
     一种实用的静态电压稳定判别新方法
短句来源
     Measurement of Voltage
     电压的测量
短句来源
     of rated voltage.
     额定电压下,出口发生三相短路时,不会造成损坏。
短句来源
     A practical method of tracing static voltage collapse point
     静态电压崩溃点的实用解法
短句来源
查询“static voltage collapse critical point”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


A new method for determination of static voltage collapse critical point based on Newton-Raphson load flow method with optimal multiplier is proposed in this paper. Different from continuation load flow and direct methods, this method starts from the infeasible region of load flow equations. It then approaches the desired critical point along the changing direction of injected power flow by making use of value of the optimal multiplier and the least square solution of load flow equations. All...

A new method for determination of static voltage collapse critical point based on Newton-Raphson load flow method with optimal multiplier is proposed in this paper. Different from continuation load flow and direct methods, this method starts from the infeasible region of load flow equations. It then approaches the desired critical point along the changing direction of injected power flow by making use of value of the optimal multiplier and the least square solution of load flow equations. All possible situations during the approaching process are analyzed and reactive power limits of generators are considered. The unified approach for identifying and calculating saddle node point and limit-induced bifurcation point is given. Convergence characteristic and computation complexity are analyzed. Tests in several systems show that the proposed method can converge at critical point after several iterations. The results are consistent with continuation load flow and direct methods.

给出了一种基于最优乘子潮流求静态电压稳定临界点的新方法。与连续潮流或直接法求解电压崩溃点不同,该方法从潮流的可行域外出发,利用潮流迭代过程中最优乘子的值和最小二乘解提供的信息,沿注入功率变化的方向逼近电压崩溃点。给出了判别和计算鞍结型和约束诱导型分岔点的方法,分析了逼近过程中的各种可能情况。对多个算例测试的结果表明:所提出的方法通过几次迭代即可收敛于静态电压稳定临界点,计算结果与应用连续潮流和直接法一致。

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关static voltage collapse critical point的内容
在知识搜索中查有关static voltage collapse critical point的内容
在数字搜索中查有关static voltage collapse critical point的内容
在概念知识元中查有关static voltage collapse critical point的内容