助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   gamma system 的翻译结果: 查询用时:0.16秒
图标索引 在分类学科中查询
所有学科
更多类别查询

图标索引 历史查询
 

gamma system
相关语句
  γ系统
     Hence, the intrafusal activity might be used as an index for studying gamma system.
     因此它可以作为研究γ系统生理学的一个简便指标。
短句来源
  “gamma system”译为未确定词的双语例句
     Methods Of 105 CCA patients treated with OUR Rotating Gamma System. The lesion diameter ranged from 0.4 to 1.8 cm (mean 1.2 cm).
     方法105例脑内海绵状血管瘤进行γ-刀治疗,病灶直径大小0.4 ̄1.8cm(平均1.2cm)。
短句来源
     Clinical application of rotating gamma system radiosurgery in neurosurgery: 2381 cases report
     旋转式γ刀在神经外科的临床应用(附2381例报告)
短句来源
     Preliminary reporting of rotating gamma system in 1431 cases of intracranial lesion
     旋转式伽玛刀治疗颅内病变1431例初步报告
短句来源
     Methods During 1998~2005,OUR Rotating Gamma System was performed in 156 patients with complete follow-up,57 males and 99 females,mean age is 57±15.GK radiosurgery was used as a first-choice treatment in 38 patients,in 98 cases had residual lesions and 20 cases with recurrent tumor.
     方法1998年至2005年,应用OUR旋转式伽玛刀治疗并有完整随访资料的颅内脑膜瘤156例,男57例、女99例,平均年龄57±15岁,首选伽玛刀治疗者38例,术后残留98例,术后复发20例。
短句来源
     An Analysis of Clinical Outcome of Whole Body Gamma System Therapy in 75 Cases with Pancreatic Carcinoma
     全身γ刀治疗胰腺癌75例临床结果分析
短句来源
更多       
  相似匹配句对
     SYSTEM
     系统
短句来源
     That system on .
     该系统基于.
短句来源
     RADIATIVE DOSIMETRY ON ROTATING GAMMA SYSTEM
     旋转式伽玛刀的辐射剂量学
短句来源
     Rotating gamma stereotactic radiosurgery system
     旋转式伽玛射线立体定向治疗系统
短句来源
查询“gamma system”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  gamma system
A variable-gamma system can significantly improve the quality of the video image by enhancing the contrast in darker parts of the image without degrading the lighter areas of the screen.
      
In this paper a variable-gamma system is discussed for application in high-quality colour television receivers.
      
The results indicate that the gamma system has an important role in enhancing information transmission from ensembles of MSs to the spinal cord.
      
However, with an operative gamma system the "ensemble effect " was much higher.
      
The stimulus was administered twice, with an operative and a disconnected gamma system.
      
更多          


Previous work showed that the discharge of intrafusal muscle fibre could be induced by needling electrode at acupuncture points of the rabbits. It was long lasting localized single unit activity. The work shows that this type of discharge at acupuncture point can be inhibited obviously during muscle isometric contrac tion elicited by stimulation of the nerve.The inhibition lasts about 20 to 80 msec. But, if the nerve innervating the muscle is cut off, the muscle contraction evoked by stimulation of the peripheral...

Previous work showed that the discharge of intrafusal muscle fibre could be induced by needling electrode at acupuncture points of the rabbits. It was long lasting localized single unit activity. The work shows that this type of discharge at acupuncture point can be inhibited obviously during muscle isometric contrac tion elicited by stimulation of the nerve.The inhibition lasts about 20 to 80 msec. But, if the nerve innervating the muscle is cut off, the muscle contraction evoked by stimulation of the peripheral end can no longer produce inhibition. The observation is exactly consistant with the results observed by Ellaway et al on autogenetic inhibition effects of gamma motoneurones. Hence, the intrafusal activity might be used as an index for studying gamma system.

本文用针电极在家兔“合谷”等穴可以引导出单位型、长持续、位置局限等为特征的梭内肌肌电发放。该肌电在刺激神经肌肉等长收缩时被明显抑制,持续约20—80毫秒,而切断神经后,则不出现抑制,与Ellaway等人关于γ运动神经元的自发抑制效应的观察结果极为一致.因此它可以作为研究γ系统生理学的一个简便指标。

The physical test of dosimetry on rotating gamma system has to be made before the clinical use of a radiation medical treatment equipment. It is a systematic test for design, processing and fabrication, fixing and electric controlling of stereotactic radiosurgical set up. The absolute dosimetry is determined using ionization chamber. The relative dose profile is measured by film. The test results are presented and discussed.

旋转式伽玛刀的辐射剂量学指标的物理测试在放射性医疗设备投放医院正式临床使用前是必不可少的,是对设备及其附件的设计、加工制造、安装以及电气控制系统等的全面综合性检定。用电离室作辐射剂量学的绝对测量,用胶片法进行相对测量,给出了测量结果并进行了讨论。

A new rotating gamma system and its clinical applications are introduced, and we compare it with stationary Gamma Knife. The results demonstrate that the former has more advantages than stationary Gamma Knife on radiation dose,processing and cost,etc.

介绍了旋转式伽玛射线立体定向治疗系统及其临床适应症,并与传统的静态聚焦伽玛刀进行了比较。结果表明前者在幅照剂量、加工、成本等性能上优于静态聚焦伽马刀,临床适用面广,疗效好。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关gamma system的内容
在知识搜索中查有关gamma system的内容
在数字搜索中查有关gamma system的内容
在概念知识元中查有关gamma system的内容
在学术趋势中查有关gamma system的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社