助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   static perimetry 的翻译结果: 查询用时:0.175秒
图标索引 在分类学科中查询
所有学科
眼科与耳鼻咽喉科
更多类别查询

图标索引 历史查询
 

static perimetry
相关语句
  静态视野
     The rate of abnormality was higher in static perimetry compared with P VEP.
     静态视野检出异常率高于P VEP。
短句来源
     Study on the light sensitivity threshold in the static perimetry and the caracters of P-VEP
     弱视眼静态视野光敏感度阈值及P一VEP变化特点的研究
短句来源
     Reliability of successive automated static perimetry
     自动静态视野随诊检查结果的可靠性研究
短句来源
     Conclusion: eye pressure test, static perimetry and P VEP examination may reflect the nerve damage in open angle glaucoma from different angles, and the results from these examinations are correlated with one another.
     结论 :眼压、静态视野、P VEP等检查方法从不同侧面揭示开角型青光眼视神经损害的程度 ,三种检查结果显著相关。
短句来源
     Methods: 22 cases (32 eyes) of primary open angle glaucoma and 30 cases (60 eyes) of normal controls were tested for eye pressure, P VEP and static perimetry. The relationship among eye pressure, P100 wave by P VEP and static visual field was analyzed.
     方法 :对 2 2例 (32只眼 )原发性开角型青光眼 ,正常对照组 30例 (6 0只眼 )进行眼压、P VEP静态视野检测 ,分析眼压、静态视野与P VEPP1 0 0波潜伏期关系 ,检测结果进行统计分析。
短句来源
更多       
  静态视野检查法
     Clinical Comparison Between TOP and DYNAMIC Automated Static Perimetry
     两种快速静态视野检查法临床应用比较
短句来源
  “static perimetry”译为未确定词的双语例句
     Automated static perimetry in high myopia
     高度近视全阈值静态中心视野改变的研究
短句来源
     Automated static perimetry in juvenile myopia with high intraocular pressure
     青少年近视合并高眼压的静态阈值视野改变
短句来源
     Prediction of future scotoma on conventional automated static perimetry using frequency doubling technology perimetry
     倍频视野计对传统自动静态视野计出现的暗点的预测性
短句来源
     A controlled study with static perimetry of different background illumination was done in 38 eases (60 eyes), with axis retrobulbar neuritis.
     本文对28例60眼球后视神经炎,采用不同背景亮度的两种自动静态视野计进行了对比检测。
短句来源
     Objective To compare and evaluate two fast automated static perimetry, TOP and DYNAMIC, used in clinic and their evaluation.
     目的比较两种快速静态阈值测定法 ,趋势导向视野检测法 (TOP)与动态平衡视野测定法 (DYNAMIC)临床应用特点及价值。
短句来源
更多       
查询“static perimetry”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  static perimetry
Automated static perimetry as a screening method for evaluation of retinal perfusion in diabetic retinopathy
      
The SLO fixation plot showed persistence of central fixation also in 1 eye in which static perimetry had not detected it.
      
Ten normal controls, ten ocular hypertensive patients, ten high tension, 12 medium tension and nine low tension glaucoma patients were studied prospectively by means of automated static perimetry.
      
In traditional static perimetry the remarkable precision achieved, resulting mainly from the lack of temporal factors related to latency, largely makes up for the relatively long time required to perform the test.
      
When assessed by static perimetry the sensitivity increase is grossly proportional with load and is thus greatest in anaerobic condition, while kinetic sensitivity differs by a sensitivity decrease when passing from aerobic to anaerobic exercise.
      
更多          


A controlled study with static perimetry of different background illumination was done in 38 eases (60 eyes), with axis retrobulbar neuritis. The results suggest that te relationship between of the average threshold in central 5°by examined with SBP-1000 type automatic perimetray and Greyscale in central 15° with TBC central visual field analyzer was contrary. The average threshold in central 5° was 8. 28±5. 13 and maximum was 18. 33. The Greyscale in central 15° was 75±9. 7 and maximum was 209. 43. In...

A controlled study with static perimetry of different background illumination was done in 38 eases (60 eyes), with axis retrobulbar neuritis. The results suggest that te relationship between of the average threshold in central 5°by examined with SBP-1000 type automatic perimetray and Greyscale in central 15° with TBC central visual field analyzer was contrary. The average threshold in central 5° was 8. 28±5. 13 and maximum was 18. 33. The Greyscale in central 15° was 75±9. 7 and maximum was 209. 43. In 4 eyes.central visual feild were normal with TBC examined (mosopic condition 4 asb).but with SBPdighting condition 31. 5 asb)examined the central threshold were unnomal.

本文对28例60眼球后视神经炎,采用不同背景亮度的两种自动静态视野计进行了对比检测。结果提示,SBP所测5°阈均值与TBC所测中心15°灰度值呈十分显著的负相关(r=0.536)。SBP中心5°阈均值为8.28±5.13,最大限度为18.33;TBC中心5°灰度值为75±68.59,最大限度为209.43。作者还将4眼TBC(半暗背景4asb)所测大致为正常的患者,又采用SBP(亮背景31.5asb)检测,结果表明:中心阈值及中心5°阈均值均有不同程度的改变。

Objcetive To study the characteristics of macular light sensitivity (MLS) and relative afferent pupillary defect (RAPD) in anisomtropic and ametropic amblyopia in school aged childern.Methods By using the static perimetry technique and swinging light test, we assessed MLS and RAPD in normal subjects,anisometropic and ametropic amblyopia in shcool aged children.Results In comparison with the normal group,the MLS in both anisometropic and ametropic amblyopic eyes was significantly depressed.The MLS...

Objcetive To study the characteristics of macular light sensitivity (MLS) and relative afferent pupillary defect (RAPD) in anisomtropic and ametropic amblyopia in school aged childern.Methods By using the static perimetry technique and swinging light test, we assessed MLS and RAPD in normal subjects,anisometropic and ametropic amblyopia in shcool aged children.Results In comparison with the normal group,the MLS in both anisometropic and ametropic amblyopic eyes was significantly depressed.The MLS of the fellow eyes of the amblyopic eyes in anisometropic subjects was also depressed as compared with that of the normal group.The rate of RAPD was positive in 34 29% in the anisometropic amblyopic group.Conclusions The static perimetry technique dmonstrates a marked depression of MLS in all amblyopic eys tested, suggesting a defct of visual X channel. The pathogenesis of monocular amblyopia and binocular amblyopia is probably different, thus MLS examination can help assess prognoss.RAPD in anisometropic amblyopia may reflect a deficiency of peripheral visual system.The fellow eye of the anisometropic amblyopia eye may also be abnormal in terms of psychophysical standard.

目的观察弱视儿童的黄斑光敏感度(macularlightsensitivity,MLS)和相对性传入性瞳孔缺陷(relativeaferentpupilarydefect,RAPD)。方法应用静态视野技术和光摆实验对正常组、屈光参差性和屈光不正性弱视的学龄儿童进行检查。结果弱视眼MLS降低(P<0.001)。屈光参差性弱视眼的对侧眼MLS也较正常组低(0.01<P<0.05)。屈光参差性弱视中,RAPD阳性者占34.29%。结论弱视存在X通道功能缺陷。单眼弱视与双眼弱视发病机制可能不同。MLS对估计预后有帮助。RAPD阳性,支持弱视的周边发生学说。屈光参差性弱视眼的对侧眼处于不正常状态。

Objective To compare and evaluate two fast automated static perimetry, TOP and DYNAMIC, used in clinic and their evaluation. Methods Sixty-one patients with normal or different kinds of visual field abnormalities accepted both TOP and DYNAMIC examinations by Octopus 101 perimetry. Results The mean examination time of TOP was 2.71min while DYNAMIC was 7.20 min. MS, MD and false positive rate showed no statistical significant difference, while LV and false negative rate did. Two fast exam methods...

Objective To compare and evaluate two fast automated static perimetry, TOP and DYNAMIC, used in clinic and their evaluation. Methods Sixty-one patients with normal or different kinds of visual field abnormalities accepted both TOP and DYNAMIC examinations by Octopus 101 perimetry. Results The mean examination time of TOP was 2.71min while DYNAMIC was 7.20 min. MS, MD and false positive rate showed no statistical significant difference, while LV and false negative rate did. Two fast exam methods were comparable. Conclusion Both TOP and DYNAMIC are effective fast visual field testing. TOP is suitable to threshold scanning or testing for all kinds of diseases; DYNAMIC is appropriate to regional or focal visual field measuring and follow-up.

目的比较两种快速静态阈值测定法 ,趋势导向视野检测法 (TOP)与动态平衡视野测定法 (DYNAMIC)临床应用特点及价值。 方法应用OCTOPUS 10 1视野计对 6 1例患者进行TOP与DYNAMIC程序视野测定。 结果TOP程序平均用时 2 .71min ,DYNAMIC程序 7.2 0min。二者测得平均缺损、假阳性率无显著差异 ;缺损方差、假阴性率存在统计学差异。两种方法测得结果有可比性。 结论TOP与DYNAMIC均为有效短时程视野程序。前者适用于各种病情总体阈值测试 ,后者倾向于局灶性视野改变的测定与随访。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关static perimetry的内容
在知识搜索中查有关static perimetry的内容
在数字搜索中查有关static perimetry的内容
在概念知识元中查有关static perimetry的内容
在学术趋势中查有关static perimetry的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社