助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   hydrogen peroxide sensor 的翻译结果: 查询用时:0.007秒
图标索引 在分类学科中查询
所有学科
自动化技术
更多类别查询

图标索引 历史查询
 

hydrogen peroxide sensor
    很抱歉,暂未找到该词条的译词。
相关语句
  “hydrogen peroxide sensor”译为未确定词的双语例句
     Study on a Hydrogen Peroxide Sensor Based on Horseradish Peroxidase/Nano-Au/Horseradish Peroxidase/Multi-walled Carbon Nanotubes
     基于辣根过氧化物酶/纳米金/辣根过氧化物酶/多壁纳米碳管修饰的过氧化氢生物传感器的研究
短句来源
     Preparation of mercapto-butanedioic acid combined nickel (Ⅱ) self-assembled monolayer modified electrode and the development of a hydrogen peroxide sensor.
     巯基丁二酸镍(Ⅱ)自组装单分子层修饰金电极的制备及H_2O_2传感器的研制
短句来源
     2 Direct potentiometric determination of H_2O_2 in waterThere is hydrogen peroxide sensor that don't need to be activated , and which has nice linear range with high sensitivity.
     二、直接电位法测定水中H_2O_2
短句来源
     On An electrode, the anion of lacunary Dawson-type tungstophosphate (P2W17 ) was doped into polypyrrole (PPy) film by electrochemical method and the PPy/P2W17/Aubased hydrogen peroxide sensor was prepared. The catalytic mechanism towards the electroreduction process of H2O2 was discussed.
     在金电极上,用电化学方法将单缺位Dawson型磷钨杂多酸盐a2-K10P2W17O6115H2O的阴离子(P2W17)掺杂到聚吡咯(PPy)薄膜中,制成PPy/P2W17/Au的H2O2传感器。
短句来源
     Consequently, a prototype hydrogen peroxide sensor is prepared. Under optimumconditions, this sensor provides a linear response over the hydrogen peroxide concentrations in the range of 1×10-6~4×10-4mol/L. The detection limit is 5×10-7mol/L.
     同时,对于过氧化氢的电化学还原表现出良好的催化活性,测定了米氏常数Km,该传感器在1×10-6~4×10-4mol/L的过氧化氢浓度范围内有良好的线性关系,检测限是5×10-7mol/L。
短句来源
更多       
  相似匹配句对
     Synthesis of Urea Hydrogen Peroxide
     过氧化氢脲合成方法的研究
短句来源
     Hydrogen peroxide for industrial use
     中华人民共和国国家标准——工业过氧化氢
短句来源
     Potato Tissue Biosensor for Hydrogen Peroxide
     马铃薯组织过氧化氢生物传感器的研究
短句来源
查询“hydrogen peroxide sensor”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  hydrogen peroxide sensor
The developed hydrogen peroxide sensor has a wide linear range of hydrogen peroxide sensing more than 140 mM and favourable dynamic response characteristics.
      
A carbon composite amperometric hydrogen peroxide sensor has been developed using a sol-gel technique.
      
Amperometric hydrogen peroxide sensor based on a sol-gel-derived ceramic carbon composite electrode with toluidine blue covalent
      
Hydrogen peroxide sensor based on horseradish peroxidase immobilized on a silver nanoparticles/cysteamine/gold electrode
      
A chemiluminometric hydrogen peroxide sensor was developed for fast flow injection analysis.
      
更多          


The catalase has been immobilized on acetyl cellulose membrane activated by pre-treatment with sodium periodate. The enzyme immobilized by covalent bounding coupled with an oxygen probe has been utilized in constructing the static or (low-through hydrogen peroxide sensor. The experimental condition for the activation of acetyl cellulose membrane and immobilization of the enzyme, as well as the measurement medium has been investigated. The linear response range for the static and flow-through versions of...

The catalase has been immobilized on acetyl cellulose membrane activated by pre-treatment with sodium periodate. The enzyme immobilized by covalent bounding coupled with an oxygen probe has been utilized in constructing the static or (low-through hydrogen peroxide sensor. The experimental condition for the activation of acetyl cellulose membrane and immobilization of the enzyme, as well as the measurement medium has been investigated. The linear response range for the static and flow-through versions of the sensor was 6. 7 X10-5~2.0X10-3 and 1. 3X 10-4~1.0X10-3mol/L, respectively. Satisfatory recoveries were obtained in the application of the proposed sensors for real sample analysis.

本文将过氧化氢酶与经活化处理的醋酸纤维膜共价固定,并与氧电极偶合,研制成静态和流通二种过氧化氢生物电极.研究了醋酸纤维膜的活化、酶的固定化、测试介质等有关的实验条件和参数、测得静态和流通二种电极响应的线性范围分别为6.7×10~(-5)~2.0×10~(-3)mol/L和1.3×10~(-1)~1.0×10~(-3)mol/L.将电极用于实际试样中的回收率测定时,获得了较好的结果.

A hydrogen peroxide sensor is made by combining oxygen eiectrode with sensitive membrane prepared by co-valently bonding hydrogen peroxide enzyme to polypropylene film . The linear range of the sensor for H2O2 is 1. 4×10-5 -1.2×10-3mol/L, and the correlation coefficient is 0. 9978. The sensor can be used at room temperatures for at least 50 days with little deterioration in response. The recoveries of H2O2 in phospbate buffer and starch solution are 98. 8% and 97.5%, respectively....

A hydrogen peroxide sensor is made by combining oxygen eiectrode with sensitive membrane prepared by co-valently bonding hydrogen peroxide enzyme to polypropylene film . The linear range of the sensor for H2O2 is 1. 4×10-5 -1.2×10-3mol/L, and the correlation coefficient is 0. 9978. The sensor can be used at room temperatures for at least 50 days with little deterioration in response. The recoveries of H2O2 in phospbate buffer and starch solution are 98. 8% and 97.5%, respectively.

将粗提纯的过氧化氢酶键合在尼龙网上制得敏化膜,再将该膜与氧电级结合制成过氧化氢传感器.测定H_2O_2的线性范围为1.4×10~(-5)~1.2×10~(-3)mol/L,相关系数0.9978.在常温下连续使用70次活性未下降,有效活性期在50天以上.在磷酸盐缓冲液和淀粉液中,H_2O_2的平均回收率分别为98.8%和97.5%.

On An electrode, the anion of lacunary Dawson-type tungstophosphate (P2W17 ) was doped into polypyrrole (PPy) film by electrochemical method and the PPy/P2W17/Aubased hydrogen peroxide sensor was prepared. The catalytic mechanism towards the electroreduction process of H2O2 was discussed. The catalytic current is proportional to the concentration of H2O2 in the range of 6. 0 × 10-5 to 8. 8 × 10-4mol/L and 8. 8 × 10-4 to 6. O× 10-3 mol/L. The detection limit is 4. 0× 10-5 mol/L. The determination of...

On An electrode, the anion of lacunary Dawson-type tungstophosphate (P2W17 ) was doped into polypyrrole (PPy) film by electrochemical method and the PPy/P2W17/Aubased hydrogen peroxide sensor was prepared. The catalytic mechanism towards the electroreduction process of H2O2 was discussed. The catalytic current is proportional to the concentration of H2O2 in the range of 6. 0 × 10-5 to 8. 8 × 10-4mol/L and 8. 8 × 10-4 to 6. O× 10-3 mol/L. The detection limit is 4. 0× 10-5 mol/L. The determination of H2O2 in simulated water samples got satisfactory results.

在金电极上,用电化学方法将单缺位Dawson型磷钨杂多酸盐a2-K10P2W17O6115H2O的阴离子(P2W17)掺杂到聚吡咯(PPy)薄膜中,制成PPy/P2W17/Au的H2O2传感器。研究了它对 H2O2电还原过程的催化机理.其 ipe与 CH2O2在 6.0× 10-5~8. 8×10-4 mol/L和8.8×10-4~6.0×10-3mol/L范围内呈良好的线性关系,检测下限为4.0×10-5mol/L。用于模拟水样中H2O2的测定,结果较满意.

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关hydrogen peroxide sensor的内容
在知识搜索中查有关hydrogen peroxide sensor的内容
在数字搜索中查有关hydrogen peroxide sensor的内容
在概念知识元中查有关hydrogen peroxide sensor的内容
在学术趋势中查有关hydrogen peroxide sensor的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社