   glucose oxidase biosensor 的翻译结果: 查询用时:0.008秒
图标索引 在分类学科中查询
所有学科
自动化技术
更多类别查询

图标索引 历史查询
 

glucose oxidase biosensor
相关语句
  葡萄糖氧化酶生物传感器
     Lactate Oxidase and Glucose Oxidase Biosensor with Ultra-fine Au Particles
     含超细Au颗粒的乳酸氧化酶和葡萄糖氧化酶生物传感器
短句来源
     Inspected the buffer solution factor such as pH value, temperature and so on, examined the influence of Cu2+ and Hg2+ to the glucose oxidase biosensor.
     考察了缓冲溶液pH值、温度等因素对葡萄糖氧化酶生物传感器检测Cu2+、Hg2+的影响。
短句来源
  “glucose oxidase biosensor”译为未确定词的双语例句
     Study on Property of Glucose Oxidase Biosensor in Organic Solution
     葡萄糖生物传感器在有机介质中的特性研究
短句来源
     3. Polyaniline glucose oxidase Biosensor Prepared with TemplateProcessA new method of preparing polyaniline (PANI) glucose oxidase sensor, which is called template process, is reported in this paper.
     通过葡萄糖酶传感器稳定性的测定可知,“模板法”制备的酶传感器的响应电流在30天仅仅下降了4.6%,而“两步法”制备的传感器的响应电流下降了55.4%。 由紫外、红外的表征可知“模板法”制备的葡萄糖氧化酶传感器中葡萄糖氧化酶与聚苯胺的结合点为其醒环上的氮原子。
短句来源
  相似匹配句对
     The glucose oxidase and its application
     葡萄糖氧化酶及其应用
短句来源
     Preparation of Glucose Oxidase Electrode
     葡萄糖氧化酶电极的制备
短句来源
     Study on Property of Glucose Oxidase Biosensor in Organic Solution
     葡萄糖生物传感器在有机介质中的特性研究
短句来源
     Biosensor based on the chitosan film immobilizing glucose oxidase
     基于壳聚糖膜固定葡萄糖氧化酶生物传感器的研究
短句来源
     Stability of Biosensors Using Covalently Immobilized Glucose Oxidase
     共价键法固定的葡萄糖氧化酶传感器稳定性研究
短句来源
查询“glucose oxidase biosensor”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  glucose oxidase biosensor
The response time of the glucose oxidase biosensor is 90 s, the detection limit is below 1 mmol/dm3 and the sensor can be used 20 times within a 2-month period without losing its stability.
      
The polyaniline/gelatin/glucose oxidase biosensor has been characterized using chemical and electrochemical methods.
      
The glucose oxidase biosensor was developed by forming a polyaniline-deposited electrode surface as support for the immobilized enzyme gel, in order to increase its durability.
      


The cyclic voltammetry property of glucose oxidase biosensor in three organic solutions with different concentrations is studied. The response current of biosensor in organic solutions is higher than that in the buffer solution. The concentration of organic solution has effect on the response of the biosensor. The optimum concentrations of organic solutions are: n-propyl alcohol 40%; ethanol 45%; acetontrile 40% respectively. The response mechanism of the biosensor is discussed.

研究了β-环糊精与二茂铁主客体葡萄糖生物传感器在正丙醇、乙醇、乙腈三种有机溶液中的循环伏安响应特性,发现该传感器在有机溶液中的响应电流较缓冲溶液中增加;且有机溶液的浓度对传感器响应产生影响,其最适百分比浓度分别为。正丙醇40%,乙醇45,乙腈40%;并探讨有机溶液对葡萄糖生物传感器产生影响的机理.

Ferroceneethylamine and chitosan were modified on a platinum eletrode by dipping method. And then,the modified electrode was sunk is glucose oxidase solution to immobilize the enzyme into the chitosan membrane. A novel glucose oxidase biosensor could be fabricated after it was finally treated with cupling reagent,glutaraldehyde. The glucose V A curve on the target biosensor has been measured. Using amperometric determination method with potential keeping constant,the current response of the...

Ferroceneethylamine and chitosan were modified on a platinum eletrode by dipping method. And then,the modified electrode was sunk is glucose oxidase solution to immobilize the enzyme into the chitosan membrane. A novel glucose oxidase biosensor could be fabricated after it was finally treated with cupling reagent,glutaraldehyde. The glucose V A curve on the target biosensor has been measured. Using amperometric determination method with potential keeping constant,the current response of the sensor is found to be linear with the glucose concentration in the range of 0 002-4 0 mmol/L with fast responese. Since 1 ferroceneehtylamine and glucose oxidase are,through the action of warp and bond,immobilized in the chitosan membrane,being not easy to be lost from electrode surface,the electrode owns high stability. It has been coupled with capillary electrophoresis to determine the glucose in human serum with satisfactory assay results.

采用浸涂法将 1 二茂铁基乙胺和壳聚糖修饰到铂电极表面 ,与葡萄糖氧化酶溶液作用后用戊二醛交联 ,制备壳聚糖固定化葡萄糖氧化酶生物传感器 ,测定葡萄糖在传感器上的伏安曲线 .采用恒电位安培检测法 ,葡萄糖浓度在 0 0 0 2~ 4 0mmol/L范围内与响应电流成线性关系 ,响应时间短 .由于二茂铁衍生物和葡萄糖氧化酶通过包埋、键合等作用固定于壳聚糖膜中 ,不易从电极表面流失 ,电极稳定性较好 .同时尝试将该电极与毛细管电泳联用 ,成功用于人血清中葡萄糖的测定 .

The work describes the original application of glucose biosensor to heavy metal determination. An inhibition detection scheme has been employed for detecting Hg2+ and Cu2+ by an established glucose biosensor modified by Prussian blue. Take Prussian blue modified electrode as the work electrode, the saturated calomel electrode as the reference electrode, another platinum electrode as the counter electrode. In three electrodes systems, carries on the scanning with thecirculation voltammetry method. Inspected the...

The work describes the original application of glucose biosensor to heavy metal determination. An inhibition detection scheme has been employed for detecting Hg2+ and Cu2+ by an established glucose biosensor modified by Prussian blue. Take Prussian blue modified electrode as the work electrode, the saturated calomel electrode as the reference electrode, another platinum electrode as the counter electrode. In three electrodes systems, carries on the scanning with thecirculation voltammetry method. Inspected the buffer solution factor such as pH value, temperature and so on, examined the influence of Cu2+ and Hg2+ to the glucose oxidase biosensor. In a wider concentration scope, the peak value electric current and the concentration of the enzyme inhibitor assumes a good linear relationship. When examines Cu2+ and Hg2+, the linear response scope respectively is 5~40μmol/l and 2.5~22.5μmol/l. The best response condition chooses the pH6.86, 25°C. The above enzyme sensor may use in domains of toxic appraisal and environmental monitoring and so on.

本文采用葡萄糖氧化酶生物传感器,利用重金属对葡萄糖氧化酶的抑制作用,来检测环境中微量的Cu2+和Hg2+浓度。以普鲁士蓝修饰的葡萄糖氧化酶电极为工作电极,饱和甘汞电极为参比电极,自制铂片电极为对电极,在三电极体系中,用循环伏安法进行扫描。考察了缓冲溶液pH值、温度等因素对葡萄糖氧化酶生物传感器检测Cu2+、Hg2+的影响。在较宽的浓度范围内,峰值电流与酶抑制剂浓度的对数呈良好的线性关系。检测Cu2+和Hg2+时,传感器的线性响应范围分别为5~40μmol/l和2.5~22.5μmol/l,最佳响应条件选择pH值为6.86,温度为25°C。上述酶传感器可用于毒性评价和环境监测等领域。

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关glucose oxidase biosensor的内容
在知识搜索中查有关glucose oxidase biosensor的内容
在数字搜索中查有关glucose oxidase biosensor的内容
在概念知识元中查有关glucose oxidase biosensor的内容
在学术趋势中查有关glucose oxidase biosensor的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社