The analysis results show: heat sinks of integrate heat pipe have good heat dissipation performance, they can control surface temperature of a CPU with power 140 W to below 45℃ when the air flow rate of fan is 0.011 5 m3/s, and they can meet high heat flux density cooling requirement of electronic apparatus.
The result indicated that its heat dissipation performance satisfied totally the 115 W CPU's heat dispel request,and indicated that only improving the motor fan's rotate speed can't increase the exchanger and the system performance efficiently.
Taguchi robust design method was applied to the design of silicon microchannel heat sinks. Reduced model for heat transfer analysis of microchannel heat sinks was built and the key parameters for their heat dissipation performance were identified. Orthogonal experiments were designed and signal-noise ratios were calculated to carry out the robust optimization of the key parameters.
Experiments have been conducted to investigate the effects of miniaturizing the base plate dimensions of horizontally-based straight rectangular fin arrays on the steady state heat dissipation performance.
The heat dissipation performance of the measuring heads is matched to the required cooling temperature.
例句来源
The temperature and flow fields of CPU heat sink Cooled by vertical jet are investigated based on numerical method. Furthermore, the recirculating flow is found under the low part of the fin, and it would deteriorate the heat dissipation at a certain degree. The heat dissipation performance of CPU heat sink cooled by vertical uniform jet is analyzed by numerical simulation under different conditions. These results are useful for the design of the heat sink wit...
AlGaN/GaN HEMT grown on sapphire substrates using FC bonding for heat dissipation is demonstrated and the mechanism of FC bonding is discussed.A model based on thermal impedance is used to analyze the heat which is dissipated by FC bonding.The tested result shows,after FC,a much reduced thermal impedance of 14.9W/(cm·K),and a increased saturation current from 300mA/mm to 396mA/mm are obtained.Source-drain current drop in high DC power is not obviously observed in FC FET.So the AlGaN/GaN ...
Based on the CFD analysis methods heat dissipation issue of electronic apparatus, simulate, and presented corresponding results. One heat sink for chip heat dissipation-heat sink of integrate heat pipe was given, and the pressure drop and the heat dissipating capacity of heat sink were investigated by altering wind velocity, working temperature of medium and pitch of fin, etc. Furthermore, simulation results are compared with experimental values and good...