blank potential
相关语句
  空白电位
     ON THE BLANK POTENTIAL VALUE OF F****-ISE AND ITS INFLUENCE ON THE RESULTS OF DETERMINATION
     论氟电极的空白电位值及其对测定结果的影响
短句来源
     A thorough study was made on the influence of the mode of washing of the fluoride ISE and the control of the blank potential value on results of determination.
     论证了氟电极的洗涤和空白电位值的控制及其对测定结果的影响;
短句来源
  空白电位值
     ON THE BLANK POTENTIAL VALUE OF F****-ISE AND ITS INFLUENCE ON THE RESULTS OF DETERMINATION
     论氟电极的空白电位值及其对测定结果的影响
短句来源
     A thorough study was made on the influence of the mode of washing of the fluoride ISE and the control of the blank potential value on results of determination.
     论证了氟电极的洗涤和空白电位值的控制及其对测定结果的影响;
短句来源
  相似匹配句对
     H. L. potential.
     H. L.
短句来源
     ON THE BLANK POTENTIAL VALUE OF F****-ISE AND ITS INFLUENCE ON THE RESULTS OF DETERMINATION
     论氟电极的空白电位值及其对测定结果的影响
短句来源
     potential of adsorbent.
     这样使吸附剂表面ζ电位降低。
短句来源
     group E: blank.
     E组:空白对照。
短句来源
     How the 'Blank' is ?
     如何“空白”?
短句来源
查询“blank potential”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


A thorough study was made on the influence of the mode of washing of the fluoride ISE and the control of the blank potential value on results of determination. It is found that the blank potential value of the F~-electrode may lead to unstable response, subjective errors, variation of range of linearity or even negative values. A method for the solution of the above mentioned questions is proposed.

论证了氟电极的洗涤和空白电位值的控制及其对测定结果的影响;提出了因氟电极空白电位值引起的稳定性和重现性差,线性范围变化及测定结果偏高、偏低甚至出现负值的解决方法.

The influence of the difference between electrode blank potential and the potential drift on the determination of fluoride by fluoride selective electrode is investigated. An one point calibration method is proposed to ensure the stability, reproducibility and accuracy in the sample analysis.

论证了测定氟化物时当氟电极洗涤的最大空白值不同和电极电位漂移的情况下 ,用一点校正法解决样品测量中的稳定性和重现性差及准确度不高的问题

The redox determination of ferric iron (such as in the analysis of iron ore) was reported to be carried out by potentiometry using Pt-electrode as the indicating electrode and standard ceric solution as titrant and in the presence of a definite amount of ferrous iron. By recording the volumes of titrant V_i with their corresponding values of potential E_i after each increment of 0.50ml of the titrant before the equivalent point and substituting the values into the derived formula, the concentration of ferric...

The redox determination of ferric iron (such as in the analysis of iron ore) was reported to be carried out by potentiometry using Pt-electrode as the indicating electrode and standard ceric solution as titrant and in the presence of a definite amount of ferrous iron. By recording the volumes of titrant V_i with their corresponding values of potential E_i after each increment of 0.50ml of the titrant before the equivalent point and substituting the values into the derived formula, the concentration of ferric iron can be calculated. It was found that the cleaning of the electrode surface, to maintain consistent blank potential values when tested with distilled water, is essential to eliminate systematic error of the working electrode.

在Fe2+存在的条件下,以铂电极为指示电极、Ce4+标准溶液为滴定剂,对氧化还原滴定计算分析法测定Fe3+进行了研究。结果表明,电极的系统误差是影响结果准确度的主要因素。

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关blank potential的内容
在知识搜索中查有关blank potential的内容
在数字搜索中查有关blank potential的内容
在概念知识元中查有关blank potential的内容
在学术趋势中查有关blank potential的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社