助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   ] axillary vein 的翻译结果: 查询用时:0.185秒
图标索引 在分类学科中查询
所有学科
临床医学
更多类别查询

图标索引 历史查询
 

axillary vein
相关语句
  相似匹配句对
     THE AXILLARY VEIN IN CHINESE
     中国人的腋静脉
短句来源
     Vein
     脉
短句来源
     A Discussion on the Formation of Axillary Vein
     腋静脉起源的探讨
短句来源
     vein gen.
     vein gen.
短句来源
     OBSERVATION ON THE AXILLARY ARTERY
     腋动脉的观察
短句来源
查询“] axillary vein”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


For the eatheterization of vein during mounting of artificial pacemaker, the morphology of the terminal part of cephalic vein in 67 Chineae adult specimens (34 male, 33 female) was observed. The results are as follows:1. The course of the terminal part of cephalic vein mostly lies in deltopeotoral triangle (116 cases of all 134 sides, 86.5%), only 10 cases (7.5%) lateral to the triangle, 7 oases (5.2%) medial to the triangle, and 1 case (0.75) absent.2. There are 129 cases (96%) of cephalic veins joining axillary...

For the eatheterization of vein during mounting of artificial pacemaker, the morphology of the terminal part of cephalic vein in 67 Chineae adult specimens (34 male, 33 female) was observed. The results are as follows:1. The course of the terminal part of cephalic vein mostly lies in deltopeotoral triangle (116 cases of all 134 sides, 86.5%), only 10 cases (7.5%) lateral to the triangle, 7 oases (5.2%) medial to the triangle, and 1 case (0.75) absent.2. There are 129 cases (96%) of cephalic veins joining axillary or subolavian ' vein directly, only 4 cases (3%) opening into external jugular vein.3. The average diameter of cephalic vein in deltopectoral triangle (2cm below coraooid process) is 3.8±0.3 (1.3-7.6mm), while the average diameter of the terminal end is 6.7±0.4 (3.4-10mm).4. In this part of cephalic vein there are more than one third of the 134 cases with no valve, about one third with one valve, and the remaining cases; less than one third with 2-3 valves.5. The average angle between cephalic and axillary (or subolavian) vein is about 53° ±0.4° (15-90°). The angle will be decreased during abduction of the arm.6. The average diameter of axillary vein is 8.6±0.2mm (5.3-12.7).

埋藏人工心搏器,新近均采用头静脉插管法。为了提供头静脉末段的形态特点,以便更有效地插管,作者观察了134侧头静脉,并将头静脉末段的形态、行径、支数、管径与腋静脉之间的角度以及头静脉的瓣膜等进行了调查和测量,还论述了此法与采用锁骨下静脉、颈内、外静脉在体表作穿刺插管的优、缺点。

In this article, the formation, length, caliber, tributary, valve and variation of the axillary veins were observed and measured in 120 upper extremities of 60 adult cadavers. The distribution of cadavers between two sexes was equal. The anatomical data of the axillary veins were presented and their clinical significance was discussed.

本文观测了60例成人尸体(男、女各半)的120侧腋静脉的合成、长度、管径、属支、瓣膜及变异等。为临床应用与国人的体质调查提供资料。

For inserting the permanent electrode introducer of the artificial pacemaker through the cephalic vein,the morphology of the terminal part of the ceph- alic vein in 70 Chinese adults cadavers (43 male,27 female) was studied.The chief results are as follows. 1)The average length of the cephalic vein in the deltopectoral groove is 11.83±0.23 cm in male and 10.88±0.21cm in female. 2)The average distance between the cephalic vein in the infraclavicular fossa and a connecting point where is situated in medial two...

For inserting the permanent electrode introducer of the artificial pacemaker through the cephalic vein,the morphology of the terminal part of the ceph- alic vein in 70 Chinese adults cadavers (43 male,27 female) was studied.The chief results are as follows. 1)The average length of the cephalic vein in the deltopectoral groove is 11.83±0.23 cm in male and 10.88±0.21cm in female. 2)The average distance between the cephalic vein in the infraclavicular fossa and a connecting point where is situated in medial two thirds and late- ral one third of the clavicle is 24.10±0.35 mm in male and 20.27±0.41mm in female. 3)The average external diameter of the cephalic vein in the infraclavicular fossa (2 cm below clavicle) is 4.08±0.15mm (1-8 mm) in male and 3.40± 0.12mm (1.8-5mm) in female. 4)The average external diameter of the terminal part of the cephalic vein is 6.26±0.22mm (3-gmm) in male,5.26±0.16mm (2.8-7mm) in female. 5)The pattern of the cephalic vein jointing with the axillary vein or the subclavian vein directly is found in 134 sides (95.71%),and the common trunk which is formed by the cephalic vein and the external superficial jugul- ar vein is found in 4 sides (2.86%).The cephalic vein is absent in 2 sides (1.43%). 6)The average angle between the cephalic vein and the axillary or subcla- vian vein is 53.83°±1.36°(30°-90°) in male,54.51°±1.63°(30°-80°) in female.The angle will be decreased during abduction of the arm.

观察了70具(140侧)成人尸体(男43,女27)的头静脉,对头静脉末段的长度、管径、汇入的深静脉及角度、体表定位、以及与肘浅静脉的关系等进行了测量和讨论。为临床上经头静脉插入导管电极安置永久性人工心脏起搏器提供了形态学依据。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关] axillary vein的内容
在知识搜索中查有关] axillary vein的内容
在数字搜索中查有关] axillary vein的内容
在概念知识元中查有关] axillary vein的内容
在学术趋势中查有关] axillary vein的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社