     Hydrogen Breathing Test in Post-gastrectomized Patients
     胃切除术后氢呼吸试验的研究
短句来源
  相似匹配句对
     Hydrogen Breathing Test in Post-gastrectomized Patients
     胃切除术后氢呼吸试验的研究
短句来源
     Breathing in Singing
     歌唱中的呼吸
短句来源
     Seeing as Breathing
     观看犹如呼吸——摄影大师马克·吕布
短句来源
     METALLIC HYDROGEN
     金属氢
短句来源
     Hydrogen Energy
     氢能
短句来源
查询“hydrogen breathing test”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


Glucose-hydrogen Breathing Test was performed by CM Hydrogen Microanalyzer in 46 peptic ulcer patients treated with cimetidine. The amount of hydrogen in expired gas was over 20 ppm in six patients. After the treatment with antibiotics the results of the test all returned to normal, indicating that there were bacteria overgrowth in small intestine in these patients and the incidence was 13.05%. The mechanism, clinical manifestations and treatment of bacteria overgrowth in small intestine...

Glucose-hydrogen Breathing Test was performed by CM Hydrogen Microanalyzer in 46 peptic ulcer patients treated with cimetidine. The amount of hydrogen in expired gas was over 20 ppm in six patients. After the treatment with antibiotics the results of the test all returned to normal, indicating that there were bacteria overgrowth in small intestine in these patients and the incidence was 13.05%. The mechanism, clinical manifestations and treatment of bacteria overgrowth in small intestine caused by cimetidine in peptic ulcer patients were discussed in brief.

采用CM型氢气微分析仪,对46例溃疡病人在服用甲氰咪呱过程中进行葡萄糖呼吸试验,发现6例肺泡呼出气含氢量>20ppm,即呼吸试验阳性。服用抗生素后复查葡萄糖呼吸试验均转阴性,提示6例阳性病人存在小肠细菌过度生长,发生率为13.05%。扼要介绍葡萄糖呼吸试验的原理、溃疡病人服用甲氰咪呱后引起小肠细菌过度生长的机理、临床表现及治疗方法。

Hydrogen level in the exhaling air after oral lactose or glucose loading was determined in normal subjects and patients after gastreetoaiy. Basal hydrogen was less than 30 ppm in all the 16 normal subjects. After lactose ingestion, 13 subjects out of the 16 (81.2%) showed an increass of hydrogen excretion of 20 ppm or more. The average peak time of hydrogen accretion was in the 3.25 hours after lactose ingestion. After glucose ingestion,the increase of hydrogen excretion was less than 20 ppm. In 7 patients with...

Hydrogen level in the exhaling air after oral lactose or glucose loading was determined in normal subjects and patients after gastreetoaiy. Basal hydrogen was less than 30 ppm in all the 16 normal subjects. After lactose ingestion, 13 subjects out of the 16 (81.2%) showed an increass of hydrogen excretion of 20 ppm or more. The average peak time of hydrogen accretion was in the 3.25 hours after lactose ingestion. After glucose ingestion,the increase of hydrogen excretion was less than 20 ppm. In 7 patients with Billroth I gastrec- tomy and 14 patients with Billroth II gastrectomy, increase of hydrogen excretion after lactose ingestion occurred in 6 out of the 7 (85.7%) and 12 out of the 14 (85.7%) respectively, which is not significantly different from that of the control. After glucose intake, increase of hydrogen excretion occurred in 1 out of the 7 (14.2%) and 5 out of the 14 (35.7%). The elevation of hydrogen in the exhaling air indicates the overgrowth of bowel bacteria. Our findings suggest that hydrogen breathing test after lactose loading is insensitive to reveal this phenomenon in patients after gastrectomy, but after glucose loading, the test might carry out this function especilly in those with Billroth II operation.

本文采用口服乳糖及葡萄糖后氢呼吸试验的方法对正常人及胃切除术后患者进行研究。结果正常人乳精呼吸试验阳性率81.2%,葡萄糖呼吸试验均正常。7例毕Ⅰ式及14例毕Ⅱ式术后患者乳精试验阳性率与正常人无显著差别(均为85.7%),但葡萄糖呼吸试验阳性率升高(14.2%~35.7%)。提示胃切除术后对乳糖呼吸试验无影响,葡萄糖呼吸试验异常,其中毕Ⅱ式较毕Ⅰ式明显。

OBJECTIVE: To find out the tolerance to lactose of Chinese. METHODS: Hydrogen breathing test (HBT) was used in 136 healthy adults of the Han nationality with different quantity of lactose A, B, C. The different groups of subjects were given 25 g, 12.5 g, 6.25 g lactose respectively. The subjects of the C group taking lactose with HBT negative were given 12.5 g lactose again were included the in D group. RESULTS: The test showed that the incidence of malabsorption for lactose of the A, B, C, D groups...

OBJECTIVE: To find out the tolerance to lactose of Chinese. METHODS: Hydrogen breathing test (HBT) was used in 136 healthy adults of the Han nationality with different quantity of lactose A, B, C. The different groups of subjects were given 25 g, 12.5 g, 6.25 g lactose respectively. The subjects of the C group taking lactose with HBT negative were given 12.5 g lactose again were included the in D group. RESULTS: The test showed that the incidence of malabsorption for lactose of the A, B, C, D groups was respectively 85.0%, 48.9%, 2% and 46.7%. The intolerance was 54.3%, 30.4%, 2.0% and 20.0% respectively. The incidence of malabsorption of and intolerance to lactose were significently different among the A, B and C groups (P<0.001). There was no significant difference between the B and D groups (P>0.05). CONCLUSION: The tolerance quantity of lactose for Chinese is 6.25 g. Taking 125 ml milk for each time is reasonable.

目的:探讨国人对乳糖耐受性。方法:采用不同剂量乳糖进行氢呼气试验。对136名健康汉族成人分为3组,A,B,C组乳糖负荷量分别为25g,12.5g,6.25g。D组为从C组氢呼气试验阴性中再给予12.5g乳糖重复试验。结果:A,B,C,D组乳糖吸收不良发生率分别为85.0%,48.9%,2.0%和46.7%;乳糖不耐受率分别为54.3%,30.4%,2.0%和20.0%。A,B,C组乳糖吸收不良发生率及乳糖不耐受率均有极显著性差异(P<0.001);B,D组间均无显著性差异(P>0.05)。结论:国人乳糖耐受量为6.25g,饮用牛奶每次以125ml为合理营养。

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关hydrogen breathing test的内容
在知识搜索中查有关hydrogen breathing test的内容
在数字搜索中查有关hydrogen breathing test的内容
在概念知识元中查有关hydrogen breathing test的内容
在学术趋势中查有关hydrogen breathing test的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社