助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   pacing electrocardiogram 的翻译结果: 查询用时:0.01秒
图标索引 在分类学科中查询
所有学科
心血管系统疾病
临床医学
生物医学工程
更多类别查询

图标索引 历史查询
 

pacing electrocardiogram
相关语句
  起搏心电图
     Compare pacing thresholds、pacing electrocardiogram and the influence of cardiac function between two sites.
     从起搏阈值、起搏心电图、及对心功能的近期影响对两部位进行比较研究。
短句来源
     tests of intravenous adenosine triphosphate(ATP) were perfomed on 18 patients with sick sinus syndrome showing sinus rate faster than pacing rate after implanting permanent VVI pacemaker. A pacing electrocardiogram, which showed that pacing and sensing functions were good, was unmasked by intravenous ATP in all these patients. The result suggests that intravenous ATP test is simple and suitable for determination of the pacing and sensing functions of nonprogramable implanted VVI pacemaker in these patients.
     对18例安置埋藏式VVI起搏器后窦性心率持续快于起搏频率的病态窦房结综合征患者施行ATP静注试验25例次,均揭示起搏心电图,显示起搏按需功能良好,结果提示,ATP静注试验适用于这类患者所安置非程控埋藏式VVI起搏器的起搏按需功能测试,其方法简便易行。
短句来源
     Results:According to these phenomena,electronic modulating T wave change and ventricular fusion wave were all the normal change of pacing electrocardiogram,and both pacing and sensing disfunctions were the characteristic of pacemaker malfunction.
     结果 :正常起搏心电图中可见室性融合波、手风琴现象及电张调整性T波改变 ,起搏器功能障碍表现为起搏与感知功能异常。
短句来源
     Guided by the QRS morphology of pacing electrocardiogram and the depth of catheter ,the success rate was 98%.
     通过起搏心电图和导管深度指导下应用漂浮电极起搏成功率98%。
短句来源
  “pacing electrocardiogram”译为未确定词的双语例句
     Evaluation of the pacemaker function by pacing electrocardiogram
     永久起搏中的心电图改变及起搏器故障的心电图判断
短句来源
     Right-ventricle-pacing method was performed on 39 cases with IVT originated from right ventricle. Ablation target site was determined when the 12-lead pacing electrocardiogram displayed QRS wave with the shape and amplitude identical to that of the IVT running.
     39例源于右心室的IVT采用消融导管右心室起搏标测法,以起搏时与室性心动过速(室速)发作时的12导联心电图QRS波形态与振幅完全相同的起搏部位为消融靶点。
短句来源
     Methods:Twelve patients undergoing RFCA were mapped. Right ventricle pacing method was performed on cases with IVT originated from right ventricle. Ablation target site was determined when the 12 lead pacing electrocardiogram displayed QRS wave with the shape and amplitude identical to that of the IVT running.
     方法:对12例IVT患者进行射频消融治疗,源于右心室IVT采用消融导管起搏标测法,以起搏时与VT发作时的12导联心电图QRS波形态与振幅完全相同的起搏部位为消融靶点。
短句来源
  相似匹配句对
     Evaluation of the pacemaker function by pacing electrocardiogram
     永久起搏中的心电图改变及起搏器故障的心电图判断
短句来源
     The Role of Dynamic Electrocardiogram in Evaluation Inappropriate Pacing
     动态心电图诊断起搏功能异常的意义
短句来源
     TRANSESOPHAGEAL PACING
     经食道快速心房起搏治疗过速性室上性心律失常
短句来源
     ELECTROCARDIOGRAM IN CARDIOMYOPATHY
     心肌病的心电图
短句来源
     electrocardiogram(ECG);
     监测心电图 ;
短句来源
查询“pacing electrocardiogram”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


Pacemaker refractory period was measured in 140 patients receiving routine permanent VVI pacemaker treatment by the pacing system analyzer, pacemaker programmer, cardiac electrophysiological programming stimulator, pacing electrocardiogram and simple calculation formula respectively. The results of all methods were compared with each other,and also compared with the values of pacemaker manfacturers. There were no significant differences among the methods,as well as each method and manufacture values. The...

Pacemaker refractory period was measured in 140 patients receiving routine permanent VVI pacemaker treatment by the pacing system analyzer, pacemaker programmer, cardiac electrophysiological programming stimulator, pacing electrocardiogram and simple calculation formula respectively. The results of all methods were compared with each other,and also compared with the values of pacemaker manfacturers. There were no significant differences among the methods,as well as each method and manufacture values. The data got from the pacemaker programmer was the most precise, and the data got from pacing electrocardiogram or calculating formula was the roughest. But as the most economical and simple way to measurre the refractory period,the latter two still were valuable methods,especially in the ordinary clinics.

对140例常规接受埋藏式VVI型起搏器治疗的患者以起搏系统分析仪、起搏器程控仪、心电生理程序刺激仪、起搏心电图以及简易折算法等测试了起搏器反拗期。各种方法之间或各种方法与起搏器出厂指标之间的起搏器反拗期值均无显著差异。唯以程控仪法为精确,而以心电图法和简易折算法为粗疏。但后二种方法经济、简便,不失为基层医疗单位初步随访、评价起搏和感知功能的可取方法之一。

tests of intravenous adenosine triphosphate(ATP) were perfomed on 18 patients with sick sinus syndrome showing sinus rate faster than pacing rate after implanting permanent VVI pacemaker. A pacing electrocardiogram, which showed that pacing and sensing functions were good, was unmasked by intravenous ATP in all these patients. The result suggests that intravenous ATP test is simple and suitable for determination of the pacing and sensing functions of nonprogramable implanted VVI pacemaker in...

tests of intravenous adenosine triphosphate(ATP) were perfomed on 18 patients with sick sinus syndrome showing sinus rate faster than pacing rate after implanting permanent VVI pacemaker. A pacing electrocardiogram, which showed that pacing and sensing functions were good, was unmasked by intravenous ATP in all these patients. The result suggests that intravenous ATP test is simple and suitable for determination of the pacing and sensing functions of nonprogramable implanted VVI pacemaker in these patients.

对18例安置埋藏式VVI起搏器后窦性心率持续快于起搏频率的病态窦房结综合征患者施行ATP静注试验25例次,均揭示起搏心电图,显示起搏按需功能良好,结果提示,ATP静注试验适用于这类患者所安置非程控埋藏式VVI起搏器的起搏按需功能测试,其方法简便易行。

The pacing impedance reflects the connection situation between pacemaker,electrodes and cardiac tissue.In this paper we have studied the method of measuring pacing system impedance from body surface. Pacing pulse could be extracted from body surface pacing electrocardiogram (ECG) signal,then pacing impedance can be calculated. This method has been used in our pacing ECG monitoring system' The system has been tested in clinic. The pacing system malfunction can be detected by analyzing...

The pacing impedance reflects the connection situation between pacemaker,electrodes and cardiac tissue.In this paper we have studied the method of measuring pacing system impedance from body surface. Pacing pulse could be extracted from body surface pacing electrocardiogram (ECG) signal,then pacing impedance can be calculated. This method has been used in our pacing ECG monitoring system' The system has been tested in clinic. The pacing system malfunction can be detected by analyzing pacing ECG and the pacing system impedance.

起搏阻抗反映了起搏器、起搏电极和心肌组织组成的起搏系统的连接状况。本文探讨了心脏起搏系统阻抗的体表检测方法,从体表起搏心电信号中分离并提取起搏脉冲波形,计算起搏系统阻抗。此方法已用于我们所研制的起搏心电监护系统,并在临床上进行了实测验证。将起搏系统阻抗和起搏心电图联系起来分析,有助于判断起搏系统故障的原因。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关pacing electrocardiogram的内容
在知识搜索中查有关pacing electrocardiogram的内容
在数字搜索中查有关pacing electrocardiogram的内容
在概念知识元中查有关pacing electrocardiogram的内容
在学术趋势中查有关pacing electrocardiogram的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社