助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   double-channel assay 的翻译结果: 查询用时:0.171秒
图标索引 在分类学科中查询
所有学科
临床医学
更多类别查询

图标索引 历史查询
 

double-channel assay
相关语句
  双通道测试
     Conclusion This simple double-channel assay procedure is accurate and reliable. It may be an effective method of sample blank compensation.
     结论双通道测试程序简单,结果准确可靠,不失为一种有效的样本空白补偿方法。
短句来源
  “double-channel assay”译为未确定词的双语例句
     Objective To design an automated double-channel assay procedure for determining serum inorganic phosphorus by UV spectrophotometry on HITACHI 7020 biochemical analyzer.
     目的设计日立7020生化仪血清无机磷紫外光度法自动双通道测定程序。
短句来源
     The sample blank error(±s) eliminated by double-channel assay in normal serum appearance samples(n=81) was 0.9%+1.7%,those in lipemia(n=38),icterus(n=32),and hemolysis samples(n=35) were 12.6%±15.4%,-5.7%±4.7%,-18.3%±14.7%,respectively.
     外观正常血清样本(n=81)双通道测定消除样本空白误差(均值±标准差)为0.9%±1.7%,脂浊(n=38)、黄胆(n=32)、溶血样本(n=35)分别为12.6%±15.4%,-5.7%±4.7%,-18.3%±14.7%。
短句来源
  相似匹配句对
     The Intelligent Double Channel Anemometer
     智能双通道风速仪
短句来源
     Channel
     水道,海峡,航道
短句来源
     ATE development of double-channel ADC
     双通道大气数据计算机自动测试设备的研制
短句来源
     The using of channel may be improved to double.
     将这一方法用于实际通信系统中会使信道利用率提高1倍。
短句来源
     Performance prediction of double-channel pumps
     双流道泵性能预测的研究
短句来源
查询“double-channel assay”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


Objective To design an automated double-channel assay procedure for determining serum inorganic phosphorus by UV spectrophotometry on HITACHI 7020 biochemical analyzer.Methods The sample blank assay channel was established for the item of inorganic phosphorus and it characteristic assay parameters including light-reading point,dual-wavelength,sample/reagent volume,K factor were the same as those of inorganic phosphorus assay channel respectively,meanwhile a compensation formula was selected...

Objective To design an automated double-channel assay procedure for determining serum inorganic phosphorus by UV spectrophotometry on HITACHI 7020 biochemical analyzer.Methods The sample blank assay channel was established for the item of inorganic phosphorus and it characteristic assay parameters including light-reading point,dual-wavelength,sample/reagent volume,K factor were the same as those of inorganic phosphorus assay channel respectively,meanwhile a compensation formula was selected and set through the compensation setup menu.Results The intra CV was 1.5%~3.0%,the inter CV was 3.0%~4.8%,and the average recovery rate was 99.5%.The sample blank error(±s) eliminated by double-channel assay in normal serum appearance samples(n=81) was 0.9%+1.7%,those in lipemia(n=38),icterus(n=32),and hemolysis samples(n=35) were 12.6%±15.4%,-5.7%±4.7%,-18.3%±14.7%,respectively.Conclusion This simple double-channel assay procedure is accurate and reliable.It may be an effective method of sample blank compensation.

目的设计日立7020生化仪血清无机磷紫外光度法自动双通道测定程序。方法建立无机磷样本空白测试通道,特征分析参数包括测光点、双波长、样本/试剂量、K值等分别与无机磷项目测试通道相同,同时在补偿项目菜单设置补偿公式。结果批内CV为1.5%~3.0%,批间CV为3.0%~4.8%,平均回收率为99.5%。外观正常血清样本(n=81)双通道测定消除样本空白误差(均值±标准差)为0.9%±1.7%,脂浊(n=38)、黄胆(n=32)、溶血样本(n=35)分别为12.6%±15.4%,-5.7%±4.7%,-18.3%±14.7%。结论双通道测试程序简单,结果准确可靠,不失为一种有效的样本空白补偿方法。

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关double-channel assay的内容
在知识搜索中查有关double-channel assay的内容
在数字搜索中查有关double-channel assay的内容
在概念知识元中查有关double-channel assay的内容
在学术趋势中查有关double-channel assay的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社