助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   plate distance 的翻译结果: 查询用时:0.009秒
图标索引 在分类学科中查询
所有学科
环境科学与资源利用
无机化工
有机化工
工业通用技术及设备
更多类别查询

图标索引 历史查询
 

plate distance
相关语句
  板间距
     FEED THROUGTPUT RELATED TO THE INCLINED PLATE DISTANCE
     斜板沉降器板间距对处理负荷的影响
短句来源
     It was found that at the same superficial gas velocity,bubble frequency and rise velocity are independent on the aperture ratio,hole diameter and baffle plate distance(the ratio of the baffle plate distance to the bed diameter is smaller than 3).
     结果表明,在一定的气速下,挡板的开孔率、孔径和板间距(级间高径比小于3)对气泡频率和气泡速度的影响较小;
短句来源
     The results show that the treatment ability increases significantly with a variation of preheating temperature from 40 ℃ to 60 ℃,in the plate distance and inclined angle there was an optimum solution.
     结果表明 ,当预热温度为 4 0℃~ 6 0℃时 ,能有效破坏分散油和乳化油的稳定性 ,处理负荷有较大提高 ,且处理负荷与斜板倾角、板间距间存在着适宜值 .
短句来源
  极板间距
     It is recommended that the 20 nF power supply capacitance and 120 mm plate distance should be choosed.
     综合考虑,建议选择电源电容20nF,极板间距120mm。
短句来源
     Adopted by electric flocculation-microfiltration,the experimental research of drinking water disinfection was developed,and the electric current density,plate distance,pH value,impact of chlorion on disinfection efficiency and the disinfection mechanism were discussed.
     本实验采用电絮凝-微滤法对饮用水进行杀菌实验的研究,并探讨了电流密度、极板间距、pH值、氯离子对杀菌效率的影响及杀菌机理。 实验表明电絮凝-微滤杀菌效果显著,且在电流密度为15.8A/m2,极板间距为1.0 cm,pH值在酸性范围内杀菌效果比较好,此外氯离子的存在有利于除菌。
短句来源
     Based on the method of Lindstedt-Poincare, the stability of the system is analyzed, the values of damping and stiffness of spring can be effect by the value of plate distance.
     采用Lindstedt-Poincare方法可以迅速而准确地分析系统的稳定边界,极板间距的取值决定了阻尼和弹簧刚度的取值范围。
短句来源
     The results showed that the ratio of wire to wire spacing to wire to plate distance at 0.8 was optimum.
     结果表明 :反应器设计中 ,电晕线间距和电晕线与极板间距之比以 0 8左右较好 ; 反应器内加折流板 ,甲苯的去除率有所提高 ;
短句来源
     increasing the plate distance will result in higher peak voltage, lower peak current and shorter width time and achieve better waveforms;
     增大极板间距,峰值电压V_p增大,峰值电流I_p减小,脉宽减小,波形更加理想;
短句来源
更多       
  板距离
     Through orthogonal experiments, the obvious sequences resulting from the effects of gaps at the two ends of an adsorber on oxygen concentration are found as following: oxygen output>upper plate distance>lower plate distance >adsorption cycle.
     通过正交实验发现吸附器两端空隙对氧气浓度影响的显著性顺序为氧气产量 >上板距离H1>下板距离H2 >吸附周期。
短句来源
  “plate distance”译为未确定词的双语例句
     INFLUENCE OF PACKING PLATE DISTANCE OF HIGH-GRAVITY ROTATING BED ON GAS PHASE RESISTANCE
     超重力旋转床片状填料间距对气相阻力的影响
短句来源
     Full effective tray with separating phase transformation and small plate distance rectifying tower
     气液隔离相变全效塔板与小板距精馏塔
短句来源
     The effects of various melt-electrospinning parameters, including melt flow index (MFI), voltage, capillary-collection plate distance, melt temperature, collection speed and PP content, on the morphology and fiber diameter of PP as well as the compatibility of PE and PP are discussed.
     利用电子拉力机测试了单根纤维的力学性能; 分析了熔融指数、电压、接收距离、熔体温度、接收速率以及PE/PP质量比等工艺参数对纤维直径、形貌以及PE/PP共混纤维中相分散程度的影响。
短句来源
     In an empty bubble column(D=140mm,L=2.5m)and a bubble column with three perforated plates of 35% aperture and plate distance of 410mm gas side and liqid side volumetric mass transfer coefficents have been measured. The experi- mental systems used were NaOH-air+CO_2 and air-water and the gas superfricial velocity range was 0.2 to 2 m/s.
     对塔径为140mm 的自由鼓泡床和内有三层间距为410mm、开孔率为35%的筛板鼓泡床,在较宽的气速(0.2
短句来源
     Using the extended Langmuir's method, an approximate expression of surface potential distributions was derived with the plate distance for asymmetric electrolytes in the case of low and moderate constant surface potential.
     根据扩展的朗格缪尔方法 ,推导出在不对称电解质中平板型颗粒在中低电位条件下的电位分布表达式。
短句来源
更多       
查询“plate distance”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  plate distance
Also, when the plate distance of the supporter from the cathode head within the reactor was 4 cm, the concentration gradients of C7H5F3 and SiH4 were the greatest.
      
The methodology is successful in providing quantitative information about the mineral area fraction, the mean plate distance or pore size and the intercept frequency as a function of angle.
      
The bases for comparison were mean plate thickness, mean plate distance, mineral area fraction, mineral volume fraction and plate orientation coupled with mechanical tests.
      
Experimental parameters were in the Reynolds number range 9200-73500, and in?the nozzle-to-plate distance range 2-10.
      
Following this, the cone-and-plate distance method, which was introduced by Jackson and Kaye, is discussed.
      
更多          


The X-ray exposures in unit of C.kg-1 or Roentgen were measured by a parallel-plate free air ionization chamber. The plate distance was 20.9cm. The length of collector was 10cm. The correction factors were determined. The uncertainty of measurement was about 1.8% for 60-2SOkV X-rays. The long-term standard deviation was ±0.1%.

本文介绍60~250kV X射线照射量的绝对测量方法,给出各种修正因子的确定结果,估计复现伦琴的不确定度为1.8%,长期重复测量的标准偏差为±0.1%。

In an empty bubble column(D=140mm,L=2.5m)and a bubble column with three perforated plates of 35% aperture and plate distance of 410mm gas side and liqid side volumetric mass transfer coefficents have been measured.The experi- mental systems used were NaOH-air+CO_2 and air-water and the gas superfricial velocity range was 0.2 to 2 m/s.The correlations obtained are as follows: k_gα=0.722u_G~(0.88) (k_Lαu_G)/g=21.1((u_Gμ_L)/σ)~(1.79)((μ_L~4g)/(ρ_Lσ~3))~(-0.248)((μ_G)/(μ_L))~(0.243)((μ_L)/(ρ_LD_L))~(-0.604)...

In an empty bubble column(D=140mm,L=2.5m)and a bubble column with three perforated plates of 35% aperture and plate distance of 410mm gas side and liqid side volumetric mass transfer coefficents have been measured.The experi- mental systems used were NaOH-air+CO_2 and air-water and the gas superfricial velocity range was 0.2 to 2 m/s.The correlations obtained are as follows: k_gα=0.722u_G~(0.88) (k_Lαu_G)/g=21.1((u_Gμ_L)/σ)~(1.79)((μ_L~4g)/(ρ_Lσ~3))~(-0.248)((μ_G)/(μ_L))~(0.243)((μ_L)/(ρ_LD_L))~(-0.604) 0.2plate column is operated under high gas velocity,air pocket will appear under the plate and is,therefore,unfavourable to mass transfer.

对塔径为140mm 的自由鼓泡床和内有三层间距为410mm、开孔率为35%的筛板鼓泡床,在较宽的气速(0.2

This work tries to produce large scale eddies by inserting an array of circular cylinders in a jet stream so that the surface renewal action is enhanced near the stagnation-point. The largest effect of heat transfer augmentation can attain 1.8 times or so in the "tree jet" case. It can be considered that the local controllability of heat treasfer distribution depends on the nozzle-to-plate distance, the cylinder pitch and diameter and cylinder array position.

通过在自由射流中设置一排圆柱列,引起大尺度旋涡,加速滞点邻近范围的表面更新作用,传热效果比自由射流强化大约180%(圆柱列顺排列时)。局部传热控制可依喷嘴宽度,喷嘴到平板之间的距离、圆柱间距和直径以及圆柱列的位置等方面考虑。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关plate distance的内容
在知识搜索中查有关plate distance的内容
在数字搜索中查有关plate distance的内容
在概念知识元中查有关plate distance的内容
在学术趋势中查有关plate distance的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社