助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   reference intensity 的翻译结果: 查询用时:0.168秒
图标索引 在分类学科中查询
所有学科
更多类别查询

图标索引 历史查询
 

reference intensity
相关语句
  参比强度
     The reference intensity K has been obtained by means of linear regression without available the pure rutile or the pure anatase.
     在没有纯金红石型或锐铁矿型标样的情况下,利用线性回归方法求出参比强度K。
短句来源
     The results show that the value obtained by analog calculation is in accordance with that obtained by reference intensity method, i.e. the K value method, if the parameters of peak shape and the peak width is chosen appropriately and there is no preferred orientation.
     结果表明 :在峰形与峰宽参数选择合适以及无择优取向的条件下 ,模拟计算结果与参比强度法也即K值法[1]测算的结果相一致。
短句来源
     Based on XRD intensity theory and molecular weight,a new approximate method to calculate reference intensity ratio(RIR) of hydro-phlogopite was proposed. The error caused by variation of molecular weight was discussed in detail and the obtained phase contents were compared with individual crystal layer method.
     以XRD强度理论和分子量为基础,建立新型水金云母(金云母-蛭石的1∶1规则间层矿物)的参比强度近似计算方法,研究水金云母分子量变化对于定量相分析结果的影响,并与已有的分晶层方法计算得到的各晶层含量进行系统比较。
短句来源
  “reference intensity”译为未确定词的双语例句
     MODIFICATION OF CALCULATED REFERENCE INTENSITY RATIO FOR X-RAY QUANTI-TATIVE PHASE ANALYSIS
     修正理论计算参考强度比值的X射线定量相分析
短句来源
     According to the parameter of unit cell structure and the atomic positions of the existing phase in positive material, the reference intensity of the ratio of the γ NiOOH (003) to the diffraction intensity of β NiOOH (001) was calculated as K=2.83.
     根据正极材料中存在相的晶体结构参数和原子位置,计算得γ-NiOOH 的(003)衍射强度与β-NiOOH 的(001)衍射强度之比的参考强度K= 2.83。
短句来源
     The reference intensity ratio is first calculated theoretically, then modified by the analogue specimens with the true physical state and the testing conditions including microabsorption, preferred orientation, monochromator and automatic divergence slit.
     再模拟样品的真实物理状态和试验条件对计算值进行修正(包括显微吸收、择尤取向、单色器和自动发散狭缝等)。
短句来源
     By using the “reference intensity ratio” method, the content of γ phase in nickel electrode was measured directly and the important parameter for the research and propriety control of electrode materials was provided.
     采用参考强度计算法可以直接、无损地测定氢氧化镍电极材料中γ相的含量,为电极材料的研制与性能控制,提供了重要的参数依据。
短句来源
     The mass fractions of crystal phases in two groups of BaOAl_2O_3SiO_2 base glass-ceramics were calculated by using the “reference intensity values” of the Joint Committee on Powder Diffraction Standards (JCPDS) determined by the crystallinity.
     采用该方法研究了不同烧结工艺制得的2组BaO Al2O3Si O2系微晶玻璃中各晶相的含量。
短句来源
  相似匹配句对
     REFERENCE
     每月参考
短句来源
     With reference to B.F.
     本文参考 B.F.
短句来源
     The Determination of the Reference Spectral Intensity of Cordierite and Mullite
     堇青石和莫来石参比强度的测定
短句来源
     The intensity of Re 197.31 is used as reference index.
     Re 197.31的发射强度被作为特定的参比指标。
短句来源
     The intensity of stresses(?)
     并计算了应力强度(?)
短句来源
查询“reference intensity”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  reference intensity
The qualitative phase analysis and quantitative phase analysis based on reference intensity ratio (RIR) method were conducted for the CPP sintered at 585, 600, 650, 700, 750, 800 and 900°C.
      
These changes are easily detected by the X-ray diffraction (XRD) technique and can be quantified from Hinckley (HI), Lietard (R2) and also reference intensity ratio (RIR) index studies.
      
The method is of the quantitative J correlation type, and the 1JC'N splitting is derived from the relative intensity in two 3D TROSY-HNCO spectra with 1JC'N dephasing intervals of ~1/(21JC'N) (reference intensity) and ~1/1JC'N (residual intensity).
      
The chrysotile quantitative determination is performed both by X-ray powder diffraction, using the internal standard and reference intensity ratio methods, and by Fourier-transform infrared absorption spectroscopy.
      
The relative intensity is the ratio of the intensity of a sound wave to a reference intensity.
      
更多          


An improved method for the quantitative X-ray phase analysis is developed. The reference intensity ratio is first calculated theoretically, then modified by the analogue specimens with the true physical state and the testing conditions including microabsorption, preferred orientation, monochromator and automatic divergence slit. Thus, its accuracy can be much improved. Result of experiment showed that this modification is available for those samples which are hard to analyse by conventional method if their...

An improved method for the quantitative X-ray phase analysis is developed. The reference intensity ratio is first calculated theoretically, then modified by the analogue specimens with the true physical state and the testing conditions including microabsorption, preferred orientation, monochromator and automatic divergence slit. Thus, its accuracy can be much improved. Result of experiment showed that this modification is available for those samples which are hard to analyse by conventional method if their crystalline structure parameters associated with the phase are given. It may be also used to verify the accuracy of the reference intensity ratio measurement and to judge by what reason the error caused.

本文介绍了一种新的X射线定量相分析方法,即首先计算出参考强度比值。再模拟样品的真实物理状态和试验条件对计算值进行修正(包括显微吸收、择尤取向、单色器和自动发散狭缝等)。用此修正值作X射线定量相分析时,可以显著提高分析结果的准确度。只要知道物相有关的晶体结构参数,就可以用本方法完成各种样品的定量分析,还可以检验实际测量的参考强度比值的准确度及解析误差来源。

The content of different types of structure titanium dioxid in industrial produces have been measured by X-ray quantitative analysis. The reference intensity K has been obtained by means of linear regression without available the pure rutile or the pure anatase. As the measuement methed is simple, precise and easy to be operated, it lays a foundantion for batch and quick measurement Titanium dioxid.

本文用X射线定量技术测定了工业生产的钛白粉中不同构型的二氧化钛的含量。在没有纯金红石型或锐铁矿型标样的情况下,利用线性回归方法求出参比强度K。测定方法简单易行,精确度高,为快速、批量测定钛白粉奠定了基础。

The advantages and drawbacks of the traditional reference schemes of optical finber displacement sensorsare analyzed,and a new reference schemes of reflective optic fiber displacement sensor which is simple,low cost andeasy to be made is presented. The ratio curve of the reference intensity and signal intensity has a good regularity. Itcan eliminate the error caused by possible unstable factors and has the potential of practical use.

分析了传统反射式光纤位移传感器参考光路的缺点,提出了一种不需要分束器或耦合器的新型参考光路,它们具有结构简单、低成本、易于制作,对光源和光纤、信号处理均无特殊要求,却能有效地消除不稳定因素影响的特点,这种传感器有实际应用的潜力。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关reference intensity的内容
在知识搜索中查有关reference intensity的内容
在数字搜索中查有关reference intensity的内容
在概念知识元中查有关reference intensity的内容
在学术趋势中查有关reference intensity的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社