voltage response time
相关语句
  “voltage response time”译为未确定词的双语例句
     The system performance parameters obtained are: voltage=1kV, current=1kA, power=1MW, switch frequency from 1 to 20kHz, voltage response time delay<120μs.
     系统技术指标达到:电压1kV,电流1kA,功率1MW,频率(1—2)kHz,系统电压响应时延<120μs。
短句来源
     The driven voltage, response time, release time and vibration modes of the capacitive switch are optimized by the Intellisuite~ TM software.
     采用Intel-lisuiteTM软件优化电容开关的驱动电压、响应时间、释放时间和机械振动模式.
短句来源
  相似匹配句对
     Improving the Transient Response Speed of Voltage Regulator
     提高电压调节器瞬态响应特性的方法
短句来源
     The Analysis of the Voltage Response of Dc-to-ac Converter
     逆变变压器电压响应分析
短句来源
     The True Response Time in Voltage Divider Measuring System
     分压器测量系统的真响应时间
短句来源
     Olfactory response of D.
     此外,被害蚕豆叶片中D对。
短句来源
     of rated voltage.
     额定电压下,出口发生三相短路时,不会造成损坏。
短句来源
查询“voltage response time”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


A 1MW fast response feedback control system for plasma equilibrium on the HT 6M tokamak, which has a thin wall vacuum vessel and a poloidal field without decoupling, has been studied and realized successfully. A GTO dc chopper is adopted for the main power supply while the switch mode control with derivative feedback loop is adopted for the main controller. The transfer function and bang bang control mode of the feedback control system are derived and studied for the system, taking account of the current...

A 1MW fast response feedback control system for plasma equilibrium on the HT 6M tokamak, which has a thin wall vacuum vessel and a poloidal field without decoupling, has been studied and realized successfully. A GTO dc chopper is adopted for the main power supply while the switch mode control with derivative feedback loop is adopted for the main controller. The transfer function and bang bang control mode of the feedback control system are derived and studied for the system, taking account of the current carrying plasma, the thin wall vacuum vessel, the feedback control field magnet, the main power supply and the controller with feedback loop. The system performance parameters obtained are: voltage=1kV, current=1kA, power=1MW, switch frequency from 1 to 20kHz, voltage response time delay<120μs. The horizontal deviation of the controlled plasma is less than ±3mm with a corresponding controllable precision better than 1.5%.

针对HT-6M托卡马克(它具有无解耦的极向场线圈系统和薄壁真空室),成功地研制出1MW快响应等离子体平衡反馈控制系统。主电源采用GTO直流斩波器。主控采用带微分反馈环节的开关斩控模式。导出了由载流等离子体、薄壁真空室和反馈场磁体所构成的反馈控制系统在Bang-Bang控制模式下的系统传递函数及控制模型。系统技术指标达到:电压1kV,电流1kA,功率1MW,频率(1—2)kHz,系统电压响应时延<120μs。在各种实验条件下,等离子体实际水平位置控制在±3mm以内,相应的控制精度优于1.5%。

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关voltage response time的内容
在知识搜索中查有关voltage response time的内容
在数字搜索中查有关voltage response time的内容
在概念知识元中查有关voltage response time的内容
在学术趋势中查有关voltage response time的内容
 
 