助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   reaction cup 的翻译结果: 查询用时:0.192秒
图标索引 在分类学科中查询
所有学科
更多类别查询

图标索引 历史查询
 

reaction cup
相关语句
  反应杯
     The Improvement of Reaction Cup for Measuring Oxygen by an Oxygen Electrode
     氧电极测氧反应杯的改进
短句来源
     Sample and KBH_4 solutions are introduced into the reaction cup with micro pipettes sequentially, then hydride generated is guide into quartz cell for atomization.
     用微量移液器加入待测溶液和硼氢化钾溶液,在反应杯中发生氢化物并导入石英管进行原子化。
短句来源
     In order to establish a quick and delicate method for environmental monitoring,the device for breath measuring which was constructed with a portable dissolved oxygen,reaction cup and a magnetic stirrer.
     为建立快速、灵敏的环境检测技术,以一台便携式溶氧仪为基础耦联反应杯、磁力搅拌器等组件装成呼吸测定装置。
短句来源
  “reaction cup”译为未确定词的双语例句
     1, 6-Hexanediol was used as a specific inhibitor for 1actate dehydrogenase (LD) M subunit in the mea-surement of LD1 isoenzyme. The first reagent containing certain concentration of 1, 6-hexanediol and serumsample were added into the reaction cup at same time on autoana1yzer(the fina1 concentration of 1, 6-Hexane-diol was 1. 16 mo1/L) and incubated at 30℃ for 5 min before adding the second reagent,and finaI1y the LD1activity was measured by enzyme linked photometry.
     本文应用1-6已二醇作为LD分子中M亚基的专一抑制剂,采用双试剂法,由自动生化分析仪直接将一定浓度的1.6-己二醇溶液(第一试剂)与血清样品同时加入反应比鱼池(加人1.6已二醇的最终浓度为1.16mol/L),于30C保温5分钟后再加入第二试剂,用酶偶联比色法测定LD;
短句来源
  相似匹配句对
     Hill reaction
     希尔反应
短句来源
     On the Extent of Reaction
     化学反应进度
短句来源
     The Improvement of Reaction Cup for Measuring Oxygen by an Oxygen Electrode
     氧电极测氧反应杯的改进
短句来源
     WUKESONG CUP
     五棵松杯
短句来源
     FOR THE WORLD CUP
     为了世界杯
短句来源
查询“reaction cup”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  reaction cup
Closing the reaction cup with a lid to avoid Mg evaporation yielded no extra loss of pore volume upon Mg-treatment as compared to open cups.
      


A micro hydride generation system is presented. Sample and KBH_4 solutions are introduced into the reaction cup with micro pipettes sequentially, then hydride generated is guide into quartz cell for atomization. The cup must be wiped with cotton for each new measurement. Accurate results are obtained for analysis of steel samples using this system.

研制了一种微型氢化物发生装置。用微量移液器加入待测溶液和硼氢化钾溶液,在反应杯中发生氢化物并导入石英管进行原子化。每次测定后用棉花球擦净。使用该装置测定钢样中的砷,获得了准确的结果。

Conventional HG-AAS needs 5-25 ml of analytical solution for each measurement, at least 1 ml. In this paper a micro hydride generation technique is presented. 20 ml of sample solution and 15ml of KBH4 solution are added in the micro reaction cup located in the hydride generation through injection port with Eppendorf pipettes sequentially, hydride generated from the reaction cup is sweep to micro heated quartz cell for atomization. We found strong suppression of Bi signals caused by Ni and Co is effectively...

Conventional HG-AAS needs 5-25 ml of analytical solution for each measurement, at least 1 ml. In this paper a micro hydride generation technique is presented. 20 ml of sample solution and 15ml of KBH4 solution are added in the micro reaction cup located in the hydride generation through injection port with Eppendorf pipettes sequentially, hydride generated from the reaction cup is sweep to micro heated quartz cell for atomization. We found strong suppression of Bi signals caused by Ni and Co is effectively eliminated by adding 8-hydroxyquinoline.

本文使用微型氢化物技术,试液和KBH_4溶液先后用微量移液管通过氢化物发生器的加液口加入反应杯。发生的氢化物由截气带入电热石英管原子化。Ni和Co对Bi信号的严重抑制可藉加入8-羟基喹啉有效地消除。

1, 6-Hexanediol was used as a specific inhibitor for 1actate dehydrogenase (LD) M subunit in the mea-surement of LD1 isoenzyme. The first reagent containing certain concentration of 1, 6-hexanediol and serumsample were added into the reaction cup at same time on autoana1yzer(the fina1 concentration of 1, 6-Hexane-diol was 1. 16 mo1/L) and incubated at 30℃ for 5 min before adding the second reagent,and finaI1y the LD1activity was measured by enzyme linked photometry. The electrophoresis pattern of LD isoenzymes...

1, 6-Hexanediol was used as a specific inhibitor for 1actate dehydrogenase (LD) M subunit in the mea-surement of LD1 isoenzyme. The first reagent containing certain concentration of 1, 6-hexanediol and serumsample were added into the reaction cup at same time on autoana1yzer(the fina1 concentration of 1, 6-Hexane-diol was 1. 16 mo1/L) and incubated at 30℃ for 5 min before adding the second reagent,and finaI1y the LD1activity was measured by enzyme linked photometry. The electrophoresis pattern of LD isoenzymes showedthat LD2-LDs activities were totalIy inhibited (under above condition). Good correlation was achieved in thecomparison between our method and the routine electrophoresis method for 5l sera (r= 0. 9885,Y= 0. 87X+18. 9). The average recovery was lO4. 4%,the linear range was up to 47O U/L at least and the CV(%)ofwithin run was 3. 83-4. 08.

本文应用1-6已二醇作为LD分子中M亚基的专一抑制剂,采用双试剂法,由自动生化分析仪直接将一定浓度的1.6-己二醇溶液(第一试剂)与血清样品同时加入反应比鱼池(加人1.6已二醇的最终浓度为1.16mol/L),于30C保温5分钟后再加入第二试剂,用酶偶联比色法测定LD;。LD同工酶电泳图谱表明在上述条件下,LD2~LDs的活性全部被抑制。用本法同常规电泳法平行检测51例血清LD,结果相关良好.r=0.9885,Y=0.87X+189;平均回收率104.4%,线性范围至少可达到470U/L;批内CV(%)为3.83~4.08。

 
<< 更多相关文摘    
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关reaction cup的内容
在知识搜索中查有关reaction cup的内容
在数字搜索中查有关reaction cup的内容
在概念知识元中查有关reaction cup的内容
在学术趋势中查有关reaction cup的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社