助手标题  
全文文献 工具书 数字 学术定义 翻译助手 学术趋势 更多
查询帮助
意见反馈
   insulating specimens 的翻译结果: 查询用时:0.007秒
图标索引 在分类学科中查询
所有学科
化学
更多类别查询

图标索引 历史查询
 

insulating specimens
相关语句
  绝缘样品
     Influence of the Magnetic Lens on XPS Analysis of Insulating Specimens
     样品磁透镜对绝缘样品XPS分析的影响
短句来源
     Peak shift and spectra distortion have been observed in XPS analysis of insulating specimens when the magnetic lens is activated. This has been attributed to the interaction between magnetic fields of the magnetic lens and low energy electrons from Al window of the twin anode X-ray source,which causes deflection of the low energy electrons,affects the quantity and distribution of the low energy electrons that reachec the sample,and so that affects the neutralization of positive charge on sample surface.
     用XPS分析绝缘样品时,启用样品磁透镜有可能引起谱峰位移和峰形畸变,其原因是磁透镜的磁场与双阳极铝窗发出的低能电子发生了相互作用,并使后者偏转,从而影响了到达样品表面起中和作用的低能电子的数量和分布.
短句来源
     It is also shown that the spectra differences caused by activating the magnetic lens and not may be used to study photoconductive phenomenon of insulating specimens.
     实验显示,用与不用磁透镜所造成的谱峰差异,有可能被用来研究绝缘样品的光导现象.
短句来源
  相似匹配句对
     Influence of the Magnetic Lens on XPS Analysis of Insulating Specimens
     样品磁透镜对绝缘样品XPS分析的影响
短句来源
     562 specimens were.
     统计562尾黑尾近红鲌标本的丰满度表明:丰满度与体长、性腺期、季节、性别有关。
短句来源
     According to the specimens of R.
     H将R .
短句来源
     TRANSFORMER INSULATING MATERIALS
     变压器绝缘材料24
短句来源
     TRANSFORMER INSULATING MATERIALS
     变压器绝缘材料(13)
短句来源
查询“insulating specimens”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
为了更好的帮助您理解掌握查询词或其译词在地道英语中的实际用法,我们为您准备了出自英文原文的大量英语例句,供您参考。
  insulating specimens
The charge build-up on the insulating specimens has proved to be the chief obstacle.
      
Charging of insulating specimens is stabilized by positive ions produced in the gas ionization cascade.
      


Peak shift and spectra distortion have been observed in XPS analysis of insulating specimens when the magnetic lens is activated.This has been attributed to the interaction between magnetic fields of the magnetic lens and low energy electrons from Al window of the twin anode X-ray source,which causes deflection of the low energy electrons,affects the quantity and distribution of the low energy electrons that reachec the sample,and so that affects the neutralization of positive charge on sample surface.It...

Peak shift and spectra distortion have been observed in XPS analysis of insulating specimens when the magnetic lens is activated.This has been attributed to the interaction between magnetic fields of the magnetic lens and low energy electrons from Al window of the twin anode X-ray source,which causes deflection of the low energy electrons,affects the quantity and distribution of the low energy electrons that reachec the sample,and so that affects the neutralization of positive charge on sample surface.It is also shown that the spectra differences caused by activating the magnetic lens and not may be used to study photoconductive phenomenon of insulating specimens.

用XPS分析绝缘样品时,启用样品磁透镜有可能引起谱峰位移和峰形畸变,其原因是磁透镜的磁场与双阳极铝窗发出的低能电子发生了相互作用,并使后者偏转,从而影响了到达样品表面起中和作用的低能电子的数量和分布.实验显示,用与不用磁透镜所造成的谱峰差异,有可能被用来研究绝缘样品的光导现象.

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关insulating specimens的内容
在知识搜索中查有关insulating specimens的内容
在数字搜索中查有关insulating specimens的内容
在概念知识元中查有关insulating specimens的内容
在学术趋势中查有关insulating specimens的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社