instantaneous fault condition
相关语句
  瞬时性故障
     By precise model of distributed parameters, running condition of a 500kV double circuit line with the non-complete phases is calculated, with or without parallel reactors. The phase relationship of voltages between fault line and no-fault lines is analyzed both under permanent fault condition and instantaneous fault condition.
     本文采用精确分布参数数学模型计算和分析了无并联电抗器的500KV同杆双回线和一侧带并联电抗器的500KV同杆双回线在永久性故障和瞬时性故障时故障线路电压与非故障线路电压之间的相位关系。
短句来源
     The integrating criterion for distinguishing permanent or instantaneous fault condition is put forward using voltage amplitude of fault-phase, phase relationship of voltages between fault line and no-fault lines, and harmonic of fault phases voltage.
     提出采用故障相电压幅值大小,故障相电压与非故障线路电压之间的相位比较,以及故障相电压谐波大小的综合判据,以区分永久性故障与瞬时性故障,实现有选择的单相自动重合闸。
短句来源
  相似匹配句对
     Adaptive Setting on Optimal Reclosing Time for Instantaneous Fault
     瞬时性故障最佳重合闸时间的自适应整定方法
短句来源
     Characteristics of Fault
     错误的特征
短句来源
     Extraction of instantaneous-fault signal in unsteady mechanical vibration signal
     非平稳机械振动噪声中瞬态故障信号的检测
短句来源
     On the Fault Culture
     断层文化论
短句来源
     the pyrolysis of biomass is instantaneous;
     生物质热解过程瞬时完成;
查询“instantaneous fault condition”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


By precise model of distributed parameters, running condition of a 500kV double circuit line with the non-complete phases is calculated, with or without parallel reactors. The phase relationship of voltages between fault line and no-fault lines is analyzed both under permanent fault condition and instantaneous fault condition. The integrating criterion for distinguishing permanent or instantaneous fault condition is put forward using voltage amplitude of fault-phase, phase relationship of voltages...

By precise model of distributed parameters, running condition of a 500kV double circuit line with the non-complete phases is calculated, with or without parallel reactors. The phase relationship of voltages between fault line and no-fault lines is analyzed both under permanent fault condition and instantaneous fault condition. The integrating criterion for distinguishing permanent or instantaneous fault condition is put forward using voltage amplitude of fault-phase, phase relationship of voltages between fault line and no-fault lines, and harmonic of fault phases voltage. By this method, the single-pole reclosing under selected condition can be completed and the impact on the power system and equipments through reclosing on the permanent fault line could be avoided.

本文采用精确分布参数数学模型计算和分析了无并联电抗器的500KV同杆双回线和一侧带并联电抗器的500KV同杆双回线在永久性故障和瞬时性故障时故障线路电压与非故障线路电压之间的相位关系。提出采用故障相电压幅值大小,故障相电压与非故障线路电压之间的相位比较,以及故障相电压谐波大小的综合判据,以区分永久性故障与瞬时性故障,实现有选择的单相自动重合闸。防止重合于故障线路造成对系统和设备的冲击。

 
图标索引 相关查询

 


 
CNKI小工具
在英文学术搜索中查有关instantaneous fault condition的内容
在知识搜索中查有关instantaneous fault condition的内容
在数字搜索中查有关instantaneous fault condition的内容
在概念知识元中查有关instantaneous fault condition的内容
在学术趋势中查有关instantaneous fault condition的内容
 
 

CNKI主页设CNKI翻译助手为主页 | 收藏CNKI翻译助手 | 广告服务 | 英文学术搜索
版权图标  2008 CNKI-中国知网
京ICP证040431号 互联网出版许可证 新出网证(京)字008号
北京市公安局海淀分局 备案号:110 1081725
版权图标 2008中国知网(cnki) 中国学术期刊(光盘版)电子杂志社