     Stator winding ground faults protection with the third harmonic current for multi-generator systems
     基于三次谐波电流的并列运行发电机定子单相接地保护
短句来源
  相似匹配句对
     Technical Measures for Parallel Running of Shunt-Excited Generators with Double-Wound Reactor
     双绕组电抗器分流励磁发电机并列运行的技术措施
短句来源
     Phase-Lead Running of a Synchronous Generator
     同步发电机的进相运行
短句来源
     Failure Analysis of Generators Operating in Parallel
     发电机并联运行故障分析
短句来源
     OPTIMAL ANALYSIS OF PARALLEL OPERATING BOILERS
     并列运行锅炉的优化分析
短句来源
     Analysis of Transformers' Parallel Operation Mode
     变压器并列运行方式的分析
短句来源
查询“并列运行发电机”译词为用户自定义的双语例句

    我想查看译文中含有:的双语例句
例句
没有找到相关例句


It is pointed out that the difference coefficients of generators running in synchronous status should be same.Based on the data of reactive power difference test for No.0 and No.3 generators of Baogang power plant,the difference characters of both generators have been calculated.The problem that the reactive power distribution between No.0 and No.3 generators of Baogang power plant does not accord with the respective unit capacity has been analyzed.It is suggested that the AVR (Automatic Voltage Regulator)difference...

It is pointed out that the difference coefficients of generators running in synchronous status should be same.Based on the data of reactive power difference test for No.0 and No.3 generators of Baogang power plant,the difference characters of both generators have been calculated.The problem that the reactive power distribution between No.0 and No.3 generators of Baogang power plant does not accord with the respective unit capacity has been analyzed.It is suggested that the AVR (Automatic Voltage Regulator)difference coefficients of the both generaors should be modified to 5% and the PSS(Power System Stabilizer) gain of No.0 generator should be increased properly.

根据宝钢电厂 0号和 3号发电机无功调差试验数据 ,计算两机调差特性 ,分析了发电机无功分配与机组容量不相配的问题 ,为此提出了对于并列运行的发电机在并列点调差系数应相等的要求 ,将两机AVR调差系数都设定为 5 %的对策 ,同时建议适当提高 0号机电力系统稳定器PSS的增益。

The principle of reactive compensator in excitation system of generator is presented.The reactive distribution among generators running in parallel is simply explained.Generator running state of Mianhuatan hydropower station is described.A constructive conceit for reactive compensation of excitation system is presented depending on test and analysis for characteristic of reactive compensation of excitation system while generator is connected as expanding unit.

阐述了发电机励磁系统中调差环节的工作原理;简单分析了并列运行发电机之间无功功率分配原理;介绍了棉花滩水电站扩大单元接线方式下发电机的运行情况,对其调差特性进行试验和分析,提出扩大单元接线方式下优化发电机励磁系统调差环节的建设性构想。

 